Histotripsy is a minimally invasive ultrasound therapy that has shown rapid liquefaction of blood clots through human skullcaps in an in vitro intracerebral hemorrhage model. However, the efficiency of these treatments can be compromised if the skull-induced aberrations are uncorrected. We have developed a catheter hydrophone which can perform aberration correction (AC) and drain the liquefied clot following histotripsy treatment. Histotripsy pulses were delivered through an excised human skullcap using a 256-element, 500-kHz hemisphere array transducer with a 15-cm focal distance. A custom hydrophone was fabricated using a 0.5 × 0.5 × 0.3 mm PZT-5h crystal interfaced to a coaxial cable and integrated into a drainage catheter. An AC algorithm was developed to correct the aberrations introduced between histotripsy pulses from each array element. An increase in focal pressure of up to 60% was achieved at the geometric focus and 27%-62% across a range of electronic steering locations. The sagittal and axial -6-dB beam widths decreased from 4.6 to 2.2 mm in the sagittal direction and 8 to 4.4 mm in the axial direction, compared to 1.5 and 3 mm in the absence of aberration. After performing AC, lesions with diameters ranging from 0.24 to 1.35 mm were generated using electronic steering over a 10×10 mm grid in a tissue-mimicking phantom. An average volume of 4.07 ± 0.91 mL was liquefied and drained after using electronic steering to treat a 4.2-mL spherical volume in in vitro bovine clots through the skullcap.
机译:组织碎裂术是一种微创超声治疗,在体外脑出血模型中,血凝块通过人的黄skull迅速液化。但是,如果未纠正颅骨引起的像差,则可能会损害这些治疗的效率。我们开发了一种导管水听器,可以进行畸变校正(AC)并在组织分裂治疗后排出液化的血凝块。使用具有15厘米焦距的256元素,500 kHz半球阵列换能器,通过切除的人的黄skull传递组织肌脉冲。使用与同轴电缆连接并集成到引流导管中的0.5×0.5×0.3 mm PZT-5h晶体制造定制的水听器。开发了一种AC算法来校正每个阵列元素在组织曲波脉冲之间引入的像差。在几何焦点上,焦压增加了60%,在一系列电子转向位置上,焦压增加了27%-62%。与没有像差时的1.5和3 mm相比,弧矢和轴向-6dB的波束宽度在弧矢方向上分别从4.6毫米减小到2.2毫米,在轴向方向上从8毫米减小到4.4毫米。进行AC后,在组织模仿体模中的10×10 mm网格上使用电子操纵产生直径范围为0.24至1.35 mm的病变。使用电子导向处理通过牛cap的体外牛血凝块中的4.2 mL球形体积后,将平均体积的4.07±0.91 mL液化并排干。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号