Radio frequency identification (RFID) tags with anisotropically conductive joints (ACAs) are used in different applications where the environmental conditions may impair their reliability. Thus the effects of different environmental stresses on reliability need to be investigated. The effects of high temperature and humidity may change the performance of the tags. Moreover, the effects of constantly varying temperature and humidity conditions may be even more harmful. In this study, the effects of changing humidity conditions on the performance of a passive ultra high frequency (UHF) RFID tag with ACA joints were studied. The tags were tested in a humidity cycling test where humidity varied from 85%RH to 10%RH, and temperature from 85 $^{circ}{rm C}$ to 25 $^{circ}{rm C}$. Tags with four different sets of bonding parameters were tested. Significant differences in the reliability between the tags with different bonding parameters were observed. The results were also compared with results from a corresponding constant humidity test where the humidity was 85%RH, and the temperature 85 $^{circ}{rm C}$. The tags had different failure times, modes, and mechanisms in these two tests. Furthermore, the effects of bonding parameters on the reliability were different in these tests. According to this study, it is important to investigate the effects of changing humidity, when the reliability in different environments is investigated, but the constant humidity test cannot be replaced with the faster humidity cycling test.
机译:具有各向异性导电接头(ACA)的射频识别(RFID)标签用于环境条件可能会削弱其可靠性的各种应用中。因此,需要研究不同环境压力对可靠性的影响。高温和高湿度的影响可能会改变标签的性能。而且,温度和湿度条件不断变化的影响可能更加有害。在这项研究中,研究了改变湿度条件对具有ACA接头的无源超高频(UHF)RFID标签性能的影响。在湿度循环测试中对标签进行了测试,其中湿度从85%RH到10%RH不等,温度从85°C到25°C。测试了具有四组不同粘合参数的标签。观察到具有不同粘合参数的标签之间的可靠性存在显着差异。还将该结果与相应的恒定湿度测试的结果进行比较,在恒定湿度测试中,湿度为85%RH,温度为85°C。在这两个测试中,标签具有不同的故障时间,模式和机制。此外,在这些测试中,粘结参数对可靠性的影响是不同的。根据这项研究,研究不同环境下的可靠性时,研究湿度变化的影响很重要,但是恒定湿度测试不能用更快的湿度循环测试代替。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号