This paper proposes a hybrid active filter for the damping of harmonic resonance in industrial power systems. The hybrid filter consists of a small-rated active filter and a 5th-tuned passive filter. The active filter is characterized by detecting the 5th-harmonic current flowing into the passive filter. It is controlled in such a way as to behave as a negative or positive resistor by adjusting a feedback gain from a negative to positive value, and vice versa. The negative resistor presented by the active filter cancels a positive resistor inherent in the passive filter, so that the hybrid filter acts as an ideal passive filter with infinite quality factor. This significantly improves damping the harmonic resonance, compared with the passive filter used alone. Moreover, the active filter acts as a positive resistor to prevent an excessive harmonic current from flowing into the passive filter. Experimental results obtained from a 20-kW laboratory model verify the viability and effectiveness of the hybrid active filter proposed in this paper.
机译:本文提出了一种用于抑制工业电力系统谐波谐振的混合有源滤波器。混合滤波器由小功率有源滤波器和第五调谐无源滤波器组成。有源滤波器的特征在于检测流入无源滤波器的5次谐波电流。通过将反馈增益从负值调整为正值来控制其表现为负电阻或正电阻,反之亦然。有源滤波器提供的负电阻消除了无源滤波器固有的正电阻,因此混合滤波器可作为具有无限品质因数的理想无源滤波器。与单独使用的无源滤波器相比,这显着改善了谐波谐振的阻尼。此外,有源滤波器用作正电阻,以防止过多的谐波电流流入无源滤波器。从20千瓦实验室模型获得的实验结果证明了本文提出的混合有源滤波器的可行性和有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号