首页> 外文期刊>IEEE Transactions on Power Electronics >Reference Current Computation Methods for Active Power Filters: Accuracy Assessment in the Frequency Domain
【24h】

Reference Current Computation Methods for Active Power Filters: Accuracy Assessment in the Frequency Domain

机译:有源功率滤波器的参考电流计算方法:频域精度评估

获取原文
获取原文并翻译 | 示例

摘要

This paper focuses on the steady-state response of existing methods for computing the reference current of active power filters. For each class of methods, the main source of discrepancy between the load harmonic current and the computed reference current is identified and the frequency spectrum of the resulting error is analytically determined. Although this topic has been partially addressed in previous publications, the proposed frequency-domain approach provides valuable qualitative information about how the errors are produced and distributed, which is masked when the analysis is carried out in the time domain. First, the frequency-domain formulation is separately presented for each method. Then, a comparison of the resulting errors is performed on a case study. Finally, some experimental results are given to validate the proposed frequency-domain analysis.
机译:本文着重介绍了用于计算有源功率滤波器参考电流的现有方法的稳态响应。对于每种方法,将确定负载谐波电流与计算出的参考电流之间差异的主要来源,并通过分析确定所产生误差的频谱。尽管在以前的出版物中已经部分解决了此主题,但是建议的频域方法提供了有关错误的产生和分布方式的有价值的定性信息,在时域中进行分析时会掩盖这些信息。首先,针对每种方法分别给出频域公式。然后,在案例研究中对结果错误进行比较。最后,给出一些实验结果以验证所提出的频域分析。

著录项