首页> 外文期刊>Power Electronics, IEEE Transactions on >Digitally Implemented Average Current-Mode Control in Discontinuous Conduction Mode PFC Rectifier
【24h】

Digitally Implemented Average Current-Mode Control in Discontinuous Conduction Mode PFC Rectifier

机译:间断导通模式PFC整流器的数字化平均电流模式控制

获取原文
获取原文并翻译 | 示例

摘要

This paper proposes a digital average current-mode control method in discontinuous conduction mode (DCM) power factor correction rectifier. The proposed control technique does not estimate, but directly senses the average value of the inductor current in each switching cycle. It is implemented by means of a conventional current sensing circuit and a microcontroller. The calculation burden of the microcontroller is the same with that of conventional two-loop-controlled converter because the additional calculation process is not required. The control method achieves lower total harmonic distortion and higher power factor than the conventional technique. Experimental results with a 200-W prototype verify the feasibility and performance of the proposed control method.
机译:提出了一种不连续导通模式功率因数校正整流器的数字平均电流模式控制方法。所提出的控制技术不进行估计,而是直接感测每个开关周期中电感器电流的平均值。它是通过传统的电流检测电路和微控制器来实现的。由于不需要额外的计算过程,因此微控制器的计算负担与传统的两环控制转换器相同。与传统技术相比,该控制方法可实现更低的总谐波失真和更高的功率因数。 200瓦原型的实验结果证明了该控制方法的可行性和性能。