The transmission lines of high-voltage networks are protected against lightning strikes and internal overvoltages with the use of overhead ground wires and surge arresters. The appropriate modelling of a power system's components is a significant issue, in order to obtain reliable theoretical simulation results for the lightning performance of the line that will be used in the design of a new line or the improvement of an existing one. Metal-oxide surge arresters present difficulties in their modelling owing to their dynamic characteristics, which depends on the rise time of the injected impulse current. Several equivalent circuit models have been proposed in the technical literature for the adequate simulation of this frequency-dependent behaviour. The current paper presents the most important surge arresters models, comparing the residual voltage that each model extracts for different lighting currents. For each model, the arresters failure probability is computed implementing them on Hellenic high-voltage transmission lines, performing a sensitivity analysis for the tower footing resistance and the arresters interval installation.
机译:高压网络的传输线使用架空接地线和避雷器来防止雷击和内部过电压。为了获得可靠的理论仿真结果,用于电力系统组件的适当建模是一个重要的问题,该理论将用于设计新线路或对现有线路进行改进的闪电性能。金属氧化物电涌放电器由于其动态特性而在建模方面存在困难,动态特性取决于注入的脉冲电流的上升时间。在技​​术文献中已经提出了几种等效电路模型,以对这种频率相关的行为进行适当的仿真。本文介绍了最重要的避雷器模型,比较了每种模型针对不同的照明电流提取的剩余电压。对于每个模型,都计算出在希腊高压输电线路上实施避雷器的失败概率,并对塔基础电阻和避雷器间隔安装进行灵敏度分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号