首页> 外文期刊>Fusion Engineering and Design >Experimental analysis of dummy load prototype for ITER coil power supply system
【24h】

Experimental analysis of dummy load prototype for ITER coil power supply system

机译:ITER线圈电源系统虚拟负载样机的实验分析

获取原文
获取原文并翻译 | 示例
           

摘要

This paper basically introduces the experimental analysis of the dummy load prototype, which aims to verify the capability of the ITER magnetic power supply systems to operate at their rated power levels without energizing the superconducting coils. The rated inductance of dummy load is 6.73mH and the pulse test currents are 45 kA, 55 kA and 68 kA. According to the requirements of the large inductance and different pulse test current classes, a dry-type air-core water-cooling prototype with epoxy resin casting technique has been fabricated, which has 24 layers and 72 turns. The experimental analyses, including the consistency test, inductance test, and temperature rise test are described in detail. The consistency of different coil layer is ensured by comparing the voltage wave under the same voltage excitation. The inductance test includes dc inductance test by using the first order circuit method and ac inductance test by LCR instrument and finite element simulation analysis. The temperature rise test results under different current classes are introduced by comparing with the simulation analyses. The above experimental results are coincided with the requirements, which shows the feasibility and availability of the prototype.
机译:本文主要介绍了虚拟负载原型的实验分析,目的在于验证ITER磁电源系统在不给超导线圈通电的情况下以其额定功率运行的能力。虚拟负载的额定电感为6.73mH,脉冲测试电流为45 kA,55 kA和68 kA。根据大电感和不同脉冲测试电流等级的要求,制作了具有环氧树脂浇铸技术的干式空心水冷原型机,该原型机有24层72匝。详细描述了实验分析,包括一致性测试,电感测试和温升测试。通过比较相同电压激励下的电压波,可以保证不同线圈层的一致性。电感测试包括采用一阶电路法的直流电感测试,采用LCR仪器的交流电感测试以及有限元仿真分析。通过与仿真分析比较,介绍了不同电流等级下的温升测试结果。以上实验结果与要求吻合,说明了原型的可行性和实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号