Four classical wet digestion procedures for the determination of mercury (Hg) by cold-vapour atomic absorption spectrometry in fish tissue were investigated with the aim of selecting and optimising the most convenient and inexpensive for use in a low technology environment. A mixture of H_2O, HNO_3, HClO_4 and H_2SO_4 or a mixture of HCl, HNO_3, HClO_4 and H_2SO_4 was used for the digestion in two different vessels namely thick walled long neck 50 ml volumetric flask and 50 ml 26 mm × 200 mm pyrex test tube. The effect of temperature and time on the digestion efficiency of the mixture of HCl, HNO_3, HClO_4 and H_2SO_4 using test tubes were investigated to obtain the optimum conditions. Mercury was partly lost at temperatures above 230 ℃ and this was pronounced when decomposition time was more than 30 min. Detection limit for the optimised procedure was 0.52 ng g~(-1). The optimised procedure was employed to study the level of Hg in canned fish samples. Concentration of Hg in the samples tested ranged from 0.015 to 0.139 μg g~(-1) wet weight.
机译:为了选择和优化在低技术环境中使用最方便,最便宜的方法,研究了四种经典的湿消化程序,用于通过冷蒸气原子吸收光谱法测定鱼组织中的汞(Hg)。使用H_2O,HNO_3,HClO_4和H_2SO_4的混合物或HCl,HNO_3,HClO_4和H_2SO_4的混合物在两个不同的容器中进行消解,即厚壁长颈50 ml容量瓶和50 ml 26 mm×200 mm派莱克斯试管。研究了温度和时间对使用试管对HCl,HNO_3,HClO_4和H_2SO_4混合物的消化效率的影响,以获得最佳条件。在高于230℃的温度下,汞会部分损失,当分解时间超过30分钟时,汞的损失尤为明显。优化程序的检出限为0.52 ng g〜(-1)。该优化程序用于研究罐头鱼样品中的汞含量。被测样品中的Hg浓度为0.015至0.139μgg〜(-1)湿重。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号