For the enumeration of Listeria monocytogenes in cold-smoked salmon, a sensitive enumeration method, based on membrane filtration followed by transfer of the filter on a selective medium, has been recently developed. An evaluation of this method was performed with several categories of foods likely to be contaminated with L. monocytogenes. The results obtained with the technique were compared with those from the reference EN ISO 11290-2 method and found to provide more precise results in the enumeration of L. monocytogenes from both artificially and naturally contaminated products. In most cases, the filtration method enabled a greater quantity of food to be examined (from around 0.5 to 14 g, instead of 0.01 to 0.1 g with the reference EN ISO 11290-2 method), thus greatly improving the sensitivity of the enumeration. Keywords Listeria monocytogenes - Enumeration - Filtration - Microbiological methods - Food An erratum to this article can be found at http://dx.doi.org/10.1007/s12161-009-9087-y
机译:为了在冷熏鲑鱼中计数单核细胞增生李斯特菌,最近已经开发了一种敏感的计数方法,该方法基于膜过滤,然后将滤膜转移到选择性培养基上。对几种可能被单核细胞增生李斯特菌污染的食品进行了该方法的评估。将该技术获得的结果与参考EN ISO 11290-2方法获得的结果进行了比较,发现在人工和自然污染产品中单核细胞增生李斯特氏菌的计数提供了更精确的结果。在大多数情况下,过滤方法可以检查更大量的食物(大约0.5到14克,而不是参考EN ISO 11290-2方法的0.01到0.1克),从而大大提高了计数的灵敏度。关键词单核细胞增生李斯特菌-计数-过滤-微生物学方法-食品有关本文的勘误,请访问http://dx.doi.org/10.1007/s12161-009-9087-y

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号