首页> 外文期刊>Food Additives & Contaminants >Migration from can coatings: Part 1. A size-exclusion chromatographic method for the simultaneous determination of overall migration and migrating substances below 1000 Da
【24h】

Migration from can coatings: Part 1. A size-exclusion chromatographic method for the simultaneous determination of overall migration and migrating substances below 1000 Da

机译:从罐涂料中的迁移:第1部分。同时进行总体迁移和1000 Da以下物质迁移的尺寸排阻色谱法

获取原文
获取原文并翻译 | 示例
           

摘要

The Council of Europe Resolution on coatings suggests a limit of 10 mg dm -2 for the sum of substances migrating into food simulants from an internal can coating. The Scientific Committee on Food differentiates the migrants into the substances with a molecular weight below 1000 Da, potentially being of toxicological concern, and the less toxicologically relevant species above 1000 Da. Hitherto, the determination of overall migration was based on a gravimetric method. A new method is described for the simultaneous determination of both overall migration and the migration of substances below 1000 Da based on separation by size exclusion chromatography (SEC) followed by ultraviolet detection (UVD) and evaporative light scattering detection (ELSD). The method is suitable for all volatile extraction media and simulants recommended by the European Union. For statistical comparison of both methods, the slightly modified reference method was validated in-house and extended to an additional gravimetric measurement of the migrants below 1000 Da. For the determination of the overall migration, both methods provided similar reproducibility (validated gravimetry: standard deviation (SD) = 0.16 mg dm(-2) ; SEC-ELSD/UVD: SD = 0.12 mg dm(-2)) but significantly better results were obtained by the SEC-ELSD/UVD method. For migrating substances below 1000 Da, the gravimetric determination provides a poor sensitivity (limit of detection = 0.35 mg dm(-2)) compared with the SEC-ELSD/UVD method (limit of detection = 0.04 mg dm(-2)). The new method offers a lower limit of detection and higher precision as well as being less time consuming and easier to use.
机译:欧洲委员会关于涂料的决议建议,从罐头内部涂料迁移到食品模拟物中的物质总量不得超过10 mg dm -2。食品科学委员会将迁移物分为分子量低于1000 Da的物质(可能具有毒理学意义)和毒理学相关性较小的物质(高于1000 Da)。迄今为止,总体迁移的确定是基于重量分析法的。描述了一种新方法,该方法可同时通过尺寸排阻色谱(SEC),紫外检测(UVD)和蒸发光散射检测(ELSD)的分离来同时测定总体迁移和1000 Da以下物质的迁移。该方法适用于欧盟推荐的所有挥发性萃取介质和模拟物。为了对这两种方法进行统计比较,对内部略微修改的参考方法进行了内部验证,并扩展到对1000 Da以下的移民进行重量分析。为了确定总迁移量,两种方法均提供了相似的重现性(验证重量法:标准偏差(SD)= 0.16 mg dm(-2); SEC-ELSD / UVD:SD = 0.12 mg dm(-2)),但效果明显更好结果是通过SEC-ELSD / UVD方法获得的。与SEC-ELSD / UVD方法(检测极限= 0.04 mg dm(-2))相比,对于迁移至1000 Da以下的物质,重量分析法提供的灵敏度较差(检测极限= 0.35 mg dm(-2))。新方法具有较低的检测下限和较高的精确度,并且耗时少且易于使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号