Sterigmatocystin (STC) is a toxic and potentially carcinogenic fungal toxin found in a variety of food commodities. This study describes the development of an analytical method to determine STC in roasted coffee beans and black pepper using ultra performance liquid chromatography (UPLC) coupled with triple quadrupole tandem mass spectrometry (MS/MS). ~(13)C_(18)-STC was used as internal standard. STC was extracted with a mixture of acetonitrile/water, diluted with a buffer, followed by purification with a solid-phase extraction and an immunoaffinity column prior to the UPLC-MS/MS analysis. Two multiple reaction monitoring (MRM) transitions were employed, one for quantification and one for confirmation of STC. The UPLC-MS/MS analytical method was validated with respect to selectivity, linearity, sensitivity, accuracy, precision, recovery, and stability. Calibration curves were linear over a concentration range 25-2,500 pg mL~(-1) with correlation coefficients (r) > 0.998. The method limit of quantification for STC in roasted coffee beans and black pepper was 0.10 ug kg"1. The accuracy and precision of the analytical method were acceptable within 15% at all quality control levels. This method was suitable to determine STC levels because of its selectivity, precision, and accuracy. The method was successfully applied to roasted coffee beans and black pepper samples.
机译:胶体去角质素(STC)是一种有毒且潜在致癌的真菌毒素,存在于多种食品中。这项研究描述了使用超高效液相色谱(UPLC)结合三重四极杆串联质谱(MS / MS)测定烘焙咖啡豆和黑胡椒中STC的分析方法的开发。 〜(13)C_(18)-STC用作内标。用乙腈/水的混合物萃取STC,用缓冲液稀释,然后用固相萃取和免疫亲和柱纯化,然后进行UPLC-MS / MS分析。使用了两个多重反应监测(MRM)转换,一个用于定量,一个用于确认STC。 UPLC-MS / MS分析方法在选择性,线性,灵敏度,准确性,精密度,回收率和稳定性方面得到了验证。校正曲线在浓度范围25-2,500 pg mL〜(-1)内呈线性,相关系数(r)> 0.998。烘焙咖啡豆和黑胡椒中STC的方法限量为0.10 ug kg“ 1。在所有质量控制水平下,分析方法的准确性和精密度在15%以内是可以接受的。该方法适用于测定STC含量,因为该方法具有很好的选择性,精密度和准确性,已成功应用于烤咖啡豆和黑胡椒样品中。

著录项

  • 来源
    《Food additives & contaminants》 |2020年第2期|355-362|共8页
  • 作者单位

    Food Research Laboratory Centre for Food Safety Food and Environmental Hygiene Department 4/F Public Health Laboratory Centre Hong Kong People's Republic of China;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Received 29 August 2019; Accepted 1 November 2019;

    机译:2019年8月29日收到;2019年11月1日接受;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号