首页> 外文期刊>European Spine Journal >Determination of axial vertebral rotation in MR images: comparison of four manual and a computerized method
【24h】

Determination of axial vertebral rotation in MR images: comparison of four manual and a computerized method

机译:MR图像中椎骨轴向旋转的确定:四种手动方法与计算机方法的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Axial vertebral rotation (AVR) of 14 normal and 14 scoliotic vertebrae from magnetic resonance (MR) images was determined by three observers using four manual methods and a computerized method, which were based on the evaluation of vertebral symmetry in two dimensions (2D) and in three dimensions (3D). The method of Aaro and Dahlborn proved to be the manual method with the highest intra-observer (1.7° SD) and inter-observer (1.2° SD) reliabilities, and was also most in agreement with the computerized method (1.3° SD, 1.0° MAD). The computerized method yielded higher intra-observer (1.3° SD) and inter-observer (1.4° SD) reliabilities than the manual methods, indicating it to be an efficient alternative for repeatable and reliable AVR measurements.
机译:由三名观察员使用四种手动方法和计算机方法,根据二维(2D)椎体对称性的评估,通过磁共振(MR)图像确定14个正常脊柱和14个脊柱侧凸椎骨的轴椎旋转度(AVR)。三维(3D)。 Aaro和Dahlborn的方法被证明是手动方法,具有最高的观察者内部(1.7°SD)和观察者间(1.2°SD)可靠性,并且与计算机化方法(1.3°SD,1.0 °MAD)。与手动方法相比,计算机化方法在观察者内部(1.3°SD)和观察者间(1.4°SD)的可靠性更高,这表明它是可重复和可靠的AVR测量的有效替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号