Axial vertebral rotation (AVR) of 14 normal and 14 scoliotic vertebrae from magnetic resonance (MR) images was determined by three observers using four manual methods and a computerized method, which were based on the evaluation of vertebral symmetry in two dimensions (2D) and in three dimensions (3D). The method of Aaro and Dahlborn proved to be the manual method with the highest intra-observer (1.7° SD) and inter-observer (1.2° SD) reliabilities, and was also most in agreement with the computerized method (1.3° SD, 1.0° MAD). The computerized method yielded higher intra-observer (1.3° SD) and inter-observer (1.4° SD) reliabilities than the manual methods, indicating it to be an efficient alternative for repeatable and reliable AVR measurements...
机译:由三名观察员使用四种手动方法和计算机方法,根据二维(2D)和二维椎体对称性的评估,确定了来自磁共振(MR)图像的14块正常脊椎和14块脊柱侧凸椎的椎体旋转(AVR)。三维(3D)。 Aaro和Dahlborn的方法被证明是手动方法,具有最高的观察者内部(1.7°SD)和观察者间(1.2°SD)可靠性,并且与计算机化方法(1.3°SD,1.0 °MAD)。与人工方法相比,计算机化方法产生的观察者内部(1.3°SD)和观察者间(1.4°SD)更高的可靠性,表明它是可重复且可靠的AVR测量的有效替代方法...