...
【24h】

Determination of axial vertebral rotation in MR images: comparison of four manual and a computerized method.

机译:MR图像中椎骨轴向旋转的确定:四种手动方法和计算机方法的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Axial vertebral rotation (AVR) of 14 normal and 14 scoliotic vertebrae from magnetic resonance (MR) images was determined by three observers using four manual methods and a computerized method, which were based on the evaluation of vertebral symmetry in two dimensions (2D) and in three dimensions (3D). The method of Aaro and Dahlborn proved to be the manual method with the highest intra-observer (1.7 degrees SD) and inter-observer (1.2 degrees SD) reliabilities, and was also most in agreement with the computerized method (1.3 degrees SD, 1.0 degrees MAD). The computerized method yielded higher intra-observer (1.3 degrees SD) and inter-observer (1.4 degrees SD) reliabilities than the manual methods, indicating it to be an efficient alternative for repeatable and reliable AVR measurements.
机译:由三名观察者使用四种手动方法和计算机方法,根据二维(2D)和第二种椎体对称性的评估,确定了来自磁共振(MR)图像的14块正常脊椎和14块脊柱侧凸椎的椎体旋转(AVR)。三维(3D)。 Aaro和Dahlborn的方法被证明是手动方法,具有最高的观察者内部(1.7度SD)和观察者间(1.2度SD)可靠性,并且与计算机方法(1.3度SD,1.0)最一致MAD)。与人工方法相比,计算机化方法在观察者内部(标度为1.3度)和观察者间(标度为1.4度)的可靠性更高,这表明它是可重复且可靠的AVR测量的有效替代方法。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号