首页> 外文期刊>European Journal of Applied Physiology >Effect of a personal ambient ventilation system on physiological strain during heat stress wearing a ballistic vest
【24h】

Effect of a personal ambient ventilation system on physiological strain during heat stress wearing a ballistic vest

机译:身穿防弹背心的个人环境通风系统对热应激期间生理张力的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The present study was conducted in order to evaluate whether physiological strain is alleviated by a new personal cooling system (CS) consisting of a layered vest and integrated blower that generate a flow of air. Twelve male volunteers were exposed to climatic conditions of 40°C, 40%RH (40/40), and 35°C, 60%RH (35/60) during a 115 min exercise routine, followed by 70 min resting recovery, while wearing a battle dress uniform (BDU) and a ballistic vest, with (COOL) or without (NOCOOL) CS. The CS was able to attenuate the physiological strain levels during exercise, when compared to identical exposures without the CS. Temperature elevation, (ΔT re) after 100 min of exercise, was lower by 0.26 ± 0.20 and 0.34 ± 0.21°C in 40/40 and 35/60, respectively, (p < 0.05). Mean skin temperature $ {left( {ifmmodeexpandafterbarelseexpandafter=fi{T}_{{{text{sk}}}} } right)} $ was lower by 0.9 ± 0.4 and 0.6 ± 0.5°C for 40/40 and 35/60, respectively. Heart rate (HR) was not significantly different for COOL versus NOCOOL for 40/40. At 35/60, HR was lower by 10 beats per min (bpm) (p < 0.05). Physiological strain index (PSI) was 9 and 21% lower for the 40/40 and 35/60, respectively, for COOL versus NOCOOL (p < 0.05). Heat storage (S) rates were 19 and 24% lower and sweat rates were 21 and 25% lower for the 40/40 and 35/60, respectively, for COOL versus NOCOOL (p < 0.05). However, the CS was not effective in alleviating physiological strain during resting recovery with no difference in T re cooling rate, S, or HR drop rate between groups over resting recovery periods. The CS tested in this study was found to be an effective tool for lowering physiological strain while exercising but not during resting recovery. Therefore, the CS should be further developed in order to achieve greater attenuation of the thermal strain during exercise and improve effectiveness during rest. Overall, it has the potential to be useful for both military and sports personnel.
机译:进行本研究是为了评估是否通过新的个人冷却系统(CS)缓解了生理压力,该系统由分层的背心和产生气流的集成鼓风机组成。在115分钟的锻炼过程中,十二名男性志愿者暴露在40°C,40%RH(40/40)和35°C,60%RH(35/60)的气候条件下,然后休息70分钟,穿着战斗服(BDU)和防弹背心,带(COOL)或不带(NOCOOL)CS。与没有CS的相同暴露相比,CS能够减弱运动过程中的生理张力水平。运动100分钟后的温度升高(ΔTre )在40/40和35/60中分别降低了0.26±0.20和0.34±0.21°C(p <0.05)。平均皮肤温度$ {左({ifmmodeexpandafterbarelseexpandafter = fi {T} _ {{{text {sk}}}}}右)} $在40/40和35/60时分别降低了0.9±0.4和0.6±0.5°C , 分别。对于40/40,COOL与NOCOOL的心率(HR)没有显着差异。在35/60时,HR降低了10次/分钟(bpm)(p <0.05)。相对于NOCOOL,COOL的40/40和35/60的生理应变指数(PSI)分别降低了9%和21%(p <0.05)。对于40/40和35/60而言,COOL与NOCOOL的热量存储(S)率分别降低19%和24%,汗水率分别降低21%和25%(p <0.05)。然而,CS在缓解静息恢复期间不能有效缓解生理紧张,并且在静息恢复期间各组之间的T resub冷却速率,S或HR下降速率没有差异。在这项研究中测试的CS被发现是一种有效的工具,可降低运动时的生理压力,但不适用于恢复静止状态。因此,应进一步开发CS,以在运动过程中获得更大的热应变衰减并提高休息时的有效性。总体而言,它有可能对军事和体育人员都有用。

著录项

  • 来源
    《European Journal of Applied Physiology》 |2008年第2期|311-319|共9页
  • 作者单位

    Heller Institute of Medical Research Sheba Medical Center 52621 Tel-Hashomer Israel;

    The Sackler Faculty of Medicine Tel Aviv University 52621 Tel Aviv Israel;

    The Sackler Faculty of Medicine Tel Aviv University 52621 Tel Aviv Israel;

    The Sackler Faculty of Medicine Tel Aviv University 52621 Tel Aviv Israel;

    The Sackler Faculty of Medicine Tel Aviv University 52621 Tel Aviv Israel;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Core temperature; Exercise; Military; Heat strain;

    机译:核心温度;运动;军事;热应变;