Accurate sodium replacement during prolonged exercise is possible when sweat rate and sweat sodium content are directly measured. Few athletes have access to sweat sodium content measurement, as the equipment needed to perform such analyzes is costly, laboratory-based or requires technical skills. Using 70 sweat samples collected in 24 athletes from 3 anatomical sites, this study determined the reliability [single-trial and inter-day (7 samples over 3 days)] and validity (instrument error) of a pocket-sized, easy-to-use and low cost sodium analyzer (Horiba C-122, Kyoto, Japan) against reference values of an ion chromatograph, the 883 Basic IC plus (Metrohm AG, Herisau, Switzerland). The Horiba C-122 showed high single-trial reliability with an intraclass correlation coefficient (ICC) of 0.997, a typical error of measurement (EM) of 1.77 mmol/L and a coefficient of variation (CV) of 3.73%. As expected, the reliability of the 883 Basic IC plus was superior to that of the Horiba C-122 (ICC: 0.999; typical EM: 0.70 mmol/L; CV: 1.52%). The Horiba’s C-122 inter-day reliability was high (ICC: 1.00; typical EM: 0.35 mmol/L). An ICC of 0.975 indicates there was a strong relationship between results provided by both analyzers. Compared with reference values, the Horiba C-122 demonstrated a mean bias of 1.71 mmol/L, a pure EM of 7.52 mmol/L and 68% limits of agreement ranging from −5.81 to 9.23 mmol/L. We propose that the Horiba C-122 is sufficiently reliable to be used under field conditions where some degree of imprecision is acceptable, but not for research purposes where high accuracy is required.
机译:直接测量出汗率和出汗钠含量可以在长时间运动中进行准确的钠替代。很少有运动员可以测量汗液中的钠含量,因为进行此类分析所需的设备昂贵,基于实验室或需要技术技能。使用从3个解剖部位的24位运动员收集的70个汗液样本,本研究确定了袖珍型,易于操作的口袋的可靠性[单次和日间(3天内有7个样本)]和有效性(仪器误差)。使用低成本钠盐分析仪(Horiba C-122,日本京都),以离子色谱仪883 Basic IC plus(瑞士Herisau的Metrohm AG)作为参考值。 Horiba C-122具有很高的单试验可靠性,组内相关系数(ICC)为0.997,典型测量误差(EM)为1.77 mmol / L,变异系数(CV)为3.73%。不出所料,883 Basic IC plus的可靠性优于Horiba C-122(ICC:0.999;典型EM:0.70 mmol / L; CV:1.52%)。 ori场C-122的日间可靠性很高(ICC:1.00;典型EM:0.35 mmol / L)。 ICC为0.975表示两个分析仪提供的结果之间存在很强的关系。与参考值相比,Horiba C-122的平均偏差为1.71 mmol / L,纯EM为7.52 mmol / L,并且协议极限为-5.81至9.23 mmol / L,范围为68%。我们建议,Horiba C-122具有足够的可靠性,可以在可接受一定程度的不精确度的野外条件下使用,但不能用于需要高精度的研究目的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号