首页> 外文期刊>Environmental quality management >Sustainable three-well pumping strategy for efficient detection monitoring near waste impoundments
【24h】

Sustainable three-well pumping strategy for efficient detection monitoring near waste impoundments

机译:可持续三大井抽油策略,用于垃圾蓄水附近的有效检测监测

获取原文
获取原文并翻译 | 示例

摘要

Efficient monitoring systems addressing the difficulty of detecting narrow contaminant plumes originating from unknown point sources are needed for modern landfills. A low-discharge extraction and accompanying injection wells could potentially address this problem. This hypothetical computer-modeling study involved a three-well detection system consisting of one extraction and two injection wells at a rectangular landfill in a shallow, unconfined aquifer. The extraction and injection wells were located near the landfill's downgradient and cross-gradient corners, respectively. Each injection well pumped at half the rate of the extraction well. A minimum pumping rate of 1.1 cubic meters per day was determined for the three-well system; at this rate, all contaminant plumes originating within the landfill's footprint entered the extraction well prior to reaching a downgradient property boundary. In comparison, five passive (not pumped) wells detected all contaminant releases from the landfill. Results of this study suggest that a low-discharge extraction well with accompanying injection wells may be an effective contaminant detection strategy at some waste impoundments.
机译:有效的监测系统解决了现代垃圾填埋场需要检测源自未知点源的窄污染羽毛。低放电提取和伴随注射井可能会解决这个问题。该假设的计算机建模研究涉及三个井检测系统,该系统包括在浅不合适的含水层的矩形垃圾填埋场中的一个提取和两个喷射孔。萃取和注入孔分别位于垃圾填埋场的下坡和交叉梯度角附近。每个喷射良好地泵送井的一半。为三大井系统确定了每天1.1立方米的最小泵送率;在此速率下,在达到降级性质边界之前,源自垃圾填埋场的占地面积的所有污染羽迹都进入了提取。相比之下,五个被动(未泵送的)孔检测到垃圾填埋场的所有污染物释放。该研究的结果表明,在一些废物蓄水中,伴随注射孔的低放电提取良好良好可能是有效的污染物检测策略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号