Dairy wastewater has been a major environmental concern because of massive effluents characterized by high pollution load. This study reports the influence of initial pH (pH_1), residence time (τ) and elapsed time (t) on the %COD removal (Y_1) and specific energy consumed (kWh per kg of COD removed. Y_2) for real dairy industry wastewater treatment in continuous stirred tank electrochemical reactor (CSTER) using aluminum electrodes. Central composite design (CCD) was applied for designing the experiments, analyzing the experimental data and optimizing the process parameters to maximizing Y_1 and simultaneously minimizing Yi. Important design parameters for continuous reactors like steady state time (ts). mass transfer coefficient (k_m) and kinetic parameters were also estimated. Modified pseudo-first-order kinetic model was used for kinetic modeling with non-linear regression technique. Experiments conducted at optimal process parameters for CSTER (pH_1= 4.5, τ= 141 min; t= 52 min) showed Y_1 = 71.21%, Y_2 = 4.
机译:乳制品废水一直是主要的环境问题,因为大量废水具有很高的污染负荷。这项研究报告了实际乳业废水中初始pH(pH_1),停留时间(τ)和经过时间(t)对%COD去除率(Y_1)和所消耗的特定能量(每千克去除COD的千瓦时。Y_2)的影响。铝电极在连续搅拌釜式电化学反应器(CSTER)中进行水处理。中央复合设计(CCD)用于设计实验,分析实验数据和优化工艺参数,以最大化Y_1并同时最小化Yi。连续反应器的重要设计参数,例如稳态时间(ts)。还估算了传质系数(k_m)和动力学参数。修改后的伪一阶动力学模型用于非线性回归技术的动力学建模。针对CSTER(pH_1 = 4.5,τ= 141 min; t = 52 min)的最佳工艺参数进行的实验显示Y_1 = 71.21%,Y_2 = 4。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号