Dynamic thermography is a promising new non-invasive diagnostic technique for melanoma screening. This paper proposes a novel experimental setup of an active cooling device for dynamic thermography using a metal disc and a Peltier module. The aim is to achieve constant cooling temperature that induce deep cooling penetration and, therefore, better thermal contrast. The paper covers the numerical analysis of the device design parameters like thermocouple position, disc thickness and regulation coefficient prior to building it. Simulation is based on a numerical model of skin tissue with melanoma and the metal disc. The Peltier module has been modeled indirectly through a boundary condition simulating the device active cooling. For effective solving of the direct problem, the BEM has been used. Results showed that the thermocouple position for cooling regulation is not as important as the value of the regulation coefficient or disc thickness. A thicker disc improves the initial cooling due to higher thermal capacity. However, a thinner disc is recommended due to the faster regulation and more constant cooling temperature. Results also showed that lesion size did not affect the cooling temperature, meaning that it can be used for investigation in any tumour stage.
机译:动态热成像是对黑色素瘤筛选的一种很有的新非侵入性诊断技术。本文提出了一种使用金属盘和珀耳帖模块的动态热成像的主动冷却装置的新型实验装置。目的是实现恒定的冷却温度,诱导深冷却渗透,因此更好地热对比度。纸张涵盖了在建筑物建筑之前的热电偶位置,盘厚度和调节系数等设备设计参数的数值分析。仿真基于皮肤瘤和金属盘的皮肤组织数值模型。 Peltier模块通过模拟设备主动冷却的边界条件间接建模。有效解决直接问题,已使用BEM。结果表明,冷却调节的热电偶位置与调节系数或圆盘厚度的值不同样重要。由于较高的热容量,较厚的盘提高了初始冷却。然而,由于更快的调节和更恒定的冷却温度,建议使用更薄的盘。结果还表明,病变尺寸不影响冷却温度,这意味着它可用于任何肿瘤阶段的研究。

著录项

  • 来源
    《Engineering analysis with boundary elements》 |2021年第4期|66-79|共14页
  • 作者单位

    Faculty of Mechanical Engineering University of Maribor Smetanova 17 Maribor SI-2000 Slovenia;

    Faculty of Mechanical Engineering University of Maribor Smetanova 17 Maribor SI-2000 Slovenia;

    Department of Civil and Environmental Engineering PUC-Rio - Pontifical Catholic University of Rio de Janeiro Rua Marques de Sao Vicente 225 Rio de Janeiro Brazil;

    Faculty of Mechanical Engineering University of Maribor Smetanova 17 Maribor SI-2000 Slovenia;

    Faculty of Mechanical Engineering University of Maribor Smetanova 17 Maribor SI-2000 Slovenia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Thermoelectric cooling; Constant temperature; Bio-heat; Peltier module; Dynamic thermography; Numerical design;

    机译:热电冷却;恒温;生物热;Peltier模块;动态热成像;数值设计;
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号