首页> 外文期刊>Energy Policy >A data-driven study of thermostat overrides during demand response events
【24h】

A data-driven study of thermostat overrides during demand response events

机译:在需求响应事件期间恒温器覆盖的数据驱动研究

获取原文
获取原文并翻译 | 示例
           

摘要

In the context of increasing renewable energy penetration in energy systems, demand response is acknowledged as a solution to guarantee grid stability and security of supply. Direct control of appliances by utilities, however, may lead to user dissatisfaction and disengagement via overrides. The present study, based on data from 6,389 connected thermostats in North America in the summer of 2019, investigates users' thermostat overriding behavior during demand response events targeting their air conditioners. An average event in this dataset was triggered around 3 p.m. and lasted three hours. The overall override rate was 12.9%. Overrides critically affected power usage during an event, with the share of the expected power demand reduction missed due to overrides being of the same order of magnitude as the override rate. In a decision tree analysis, the override rate showed to be particularly affected by occupants' habitual setpoint change frequency, outdoor temperature, event duration, and occupants' previous experience with demand response. Even though the dataset is not representative of all types of demand response events, this study highlights the potential lying in connected thermostat data for utilities to design tailored demand response events with an increased success rate and a smaller impact on occupant comfort.
机译:在增加能源系统中可再生能源渗透的背景下,需求响应被确认为保证电网稳定性和供应安全性的解决方案。然而,利用公用事业的直接控制可能导致用户不满和脱离通过覆盖。本研究基于2019年夏季北美的6,389张连接恒温器的数据,调查用户在需求响应事件中的恒温超出行为,瞄准其空调。此数据集中的平均事件截至3下午3点触发。并持续了三个小时。整体超额率为12.9%。在活动期间覆盖严重影响的电力使用情况,由于覆盖与覆盖速率相同的数量级覆盖,因此占据预期功率需求的份额。在决策树分析中,覆盖速率显示占用者习惯设定值改变频率,室外温度,事件持续时间和乘员以前的需求响应经验。即使数据集没有代表所有类型的需求响应事件,这项研究突出了在适用于公用事业公司的连接恒温器数据中的潜力,以增加成功率增加,对乘员舒适性的影响较小。

著录项

  • 来源
    《Energy Policy》 |2021年第6期|112290.1-112290.14|共14页
  • 作者单位

    Tech Univ Denmark Dept Civil Engn DK-2800 Lyngby Denmark|St Gobain Nordic AS Robert Jacobsens Vej 62A DK-2300 Copenhagen Denmark;

    Carleton Univ Dept Civil & Environm Engn 1125 Colonel Dr Ottawa ON K1S 5B6 Canada;

    Carleton Univ Dept Civil & Environm Engn 1125 Colonel Dr Ottawa ON K1S 5B6 Canada;

    Tech Univ Denmark Dept Civil Engn DK-2800 Lyngby Denmark;

    Tech Univ Denmark Dept Civil Engn DK-2800 Lyngby Denmark;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Demand response; Connected thermostat; Occupant behavior; Override; Decision tree;

    机译:需求响应;连接恒温器;占用行为;覆盖;决策树;