In this work, a novel vapour-liquid channel-separated ultra-thin (0.4-mm-thick) vapour chamber fabricated via etching and diffusion bonding was designed for cooling electronic devices. The heat performance of ultra-thin vapour chamber was tested under five states, and micropillar arrays were etched into the chamber to study their effect on heat transfer. Additionally, infrared thermal imaging was performed to investigate the heat dissipation of cooling modules with and without the ultra-thin vapour chamber. The maximum heat transfer capacity of the ultra-thin vapour chamber in the horizontal state was 4.50 W, and the temperature difference was 4.75 degrees C. The experimentally measured values were very close to the theoretical capillary limit. Under normal and reverse gravities, the maximum heat transfer capacity changed by less than 11%. The effective thermal conductivity of the ultra-thin vapour chamber was 12000 W/(m.K), which is 30 times higher than that of pure copper. The cooling module with the ultra-thin vapour chamber exhibited better heat dissipation, thermal uniformity and thermal response properties. When the heating input power was 6 W, the heating block temperature, maximum surface temperature difference and equilibrium time of the cooling module with the ultra-thin vapour chamber were 8%, 54% and 32% lower, respectively, than those of the module without the ultra-thin vapour chamber. The proposed cooling solution is promising for heat dissipation problems in high-power portable electronic devices.
机译:在这项工作中,设计了一种通过蚀刻和扩散结合制成的新颖的气液通道分离超薄(0.4毫米厚)蒸气室,用于冷却电子设备。在五个状态下测试了超薄蒸气室的热性能,并将微柱阵列蚀刻到该室中以研究其对热传递的影响。此外,进行了红外热成像以研究带有和不带有超薄蒸气室的冷却模块的散热情况。水平状态下的超薄蒸气室的最大传热容量为4.50 W,温度差为4.75摄氏度。实验测量值非常接近理论毛细管极限。在正向和反向重力作用下,最大传热能力变化不到11%。超薄蒸气室的有效热导率为12000 W /(m.K),是纯铜的30倍。具有超薄蒸气室的冷却模块具有更好的散热,热均匀性和热响应特性。当加热输入功率为6 W时,带有超薄蒸气室的冷却模块的加热块温度,最大表面温差和平衡时间分别比模块的温度低8%,54%和32%。没有超薄蒸气室所提出的冷却解决方案有望解决大功率便携式电子设备中的散热问题。

著录项

  • 来源
    《Energy Conversion & Management》 |2019年第5期|221-231|共11页
  • 作者单位

    South China Univ Technol, Sch Mech & Automot Engn, Guangzhou 510640, Guangdong, Peoples R China;

    South China Univ Technol, Sch Mech & Automot Engn, Guangzhou 510640, Guangdong, Peoples R China;

    South China Univ Technol, Sch Mech & Automot Engn, Guangzhou 510640, Guangdong, Peoples R China;

    South China Univ Technol, Sch Mech & Automot Engn, Guangzhou 510640, Guangdong, Peoples R China;

    Univ Nottingham, Fluids & Thermal Engn Res Grp, Fac Engn, Nottingham, England|Univ Nottingham, Ctr Fluids & Thermal Engn Res, Ningbo, Zhejiang, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ultra-thin vapour chamber; Vapour-liquid channel separation; Mesh wick; Cooling module; Thermal performance; Heat dissipation;