首页> 外文期刊>IEEE Transactions on Energy Conversion >Should existing pressure vessel regulations apply to gas filled electrical equipment-an electrical engineer's viewpoint
【24h】

Should existing pressure vessel regulations apply to gas filled electrical equipment-an electrical engineer's viewpoint

机译:现行压力容器法规是否应适用于充气电气设备-电气工程师的观点

获取原文
获取原文并翻译 | 示例

摘要

Electrical equipment which uses an inert gas, sulfur hexafluoride, has been in commercial use for several decades and is today the most dominant design technology for high-voltage substation equipment. Sulfur hexafluoride gas possesses excellent electrical-insulation and arc-quenching properties. making it suitable for the design of circuit breakers, instrument transformers, bus ducts, and total gas-insulated metal-clad substations (GIS). The gas properties require that only modest equipment design pressures of 400 to 700 kPa (60 to 102 psig) be used. However. these pressures are sufficient to classify the equipment as a pressure vessel under many local boiler and pressure-vessel safety laws. New CENELEC standards, written specifically for this gas-filled equipment, should provide a logical basis for the future electrical industry regulation of this specialized equipment.
机译:使用惰性气体六氟化硫的电气设备已经在商业上使用了几十年,今天已成为高压变电站设备最主要的设计技术。六氟化硫气体具有出色的电绝缘和灭弧性能。适用于断路器,仪表变压器,母线槽和气体绝缘的金属包覆的变电站(GIS)的设计。气体特性要求仅使用400至700 kPa(60至102 psig)的中等设备设计压力。然而。根据许多当地锅炉和压力容器安全法规,这些压力足以将设备归类为压力容器。专为这种充气设备编写的新的CENELEC标准应为该专用设备的未来电气行业法规提供逻辑依据。