首页> 外文期刊>Electronics and Communications in Japan >Crosstalk Analysis Model for Traces Crossing Split Ground Plane and Its Reduction by Stitching Capacitor
【24h】

Crosstalk Analysis Model for Traces Crossing Split Ground Plane and Its Reduction by Stitching Capacitor

机译:跨越分离平面的迹线串扰分析模型及其缝合电容器的减少

获取原文
获取原文并翻译 | 示例
           

摘要

Crosstalk and its reduction by using stitching capacitors for traces crossing split ground plane are investigated in this paper. While two traces cross the same slot in the ground plane, the crosstalk between them will be of very high level, even if they are far apart. By examining the measured S-parameter and near-magnetic field, we concluded that the crosstalk is due to magnetic or inductive coupling between the trace and the slot in the ground. We therefore developed an equivalent circuit model for characterizing the crosstalk. The validity of the equivalent circuit model is verified by comparison with measurement results. The reduction of crosstalk by stitching the split ground plane with capacitors is discussed on the basis of the developed equivalent circuit model.
机译:本文研究了串扰及其通过使用缝线电容器跨越分离的接地平面的迹线来减少。尽管两条走线在接地平面上穿过同一插槽,但即使它们相距很远,它们之间的串扰也会非常高。通过检查测得的S参数和近磁场,我们得出结论,串扰是由于走线与地面中的槽之间的磁耦合或电感耦合引起的。因此,我们开发了用于表征串扰的等效电路模型。通过与测量结果进行比较,验证了等效电路模型的有效性。在已开发的等效电路模型的基础上,讨论了通过用电容器缝合分离的接地层来减少串扰。