This paper presents a general method, experimentally validated, highlighting the influence of the number of stirring configurations used during radiated susceptibility tests performed in reverberation chambers in terms of reliability and confidence of the obtained results. This Monte-Carlo based approach (with routines available on demand) computes the risk to declare compliant from an electromagnetic compatibility (EMC) point of view a faulty equipment under test. This risk is calculated according to the number of stirring configurations chosen for the test and to the uncertainty of the electromagnetic field strength applied on the equipment. The proposed method is shown to be applicable for any equipment independently of its size and directivity (or more precisely its receiving polarization pattern). Overtesting is shown in this context to be a promising solution able to increase the confidence of the users about the EMC compliance of tested equipment. The paper also illustrates the possibility to extract the minimum susceptibility level of a valid EUT as a function of the testing conditions.
机译:本文介绍了一般方法,实验验证,突出了在所获得的结果的可靠性和置信方面在混响室中进行的辐射易感性试验期间使用的搅拌配置的影响。基于Monte-Carlo基于Monte-Carlo的方法(随需按要求提供的例程)计算从电磁兼容性(EMC)视角的符合声明的风险。根据所选择的搅拌配置数以及在设备上施加的电磁场强度的不确定性来计算这种风险。所提出的方法被示出适用于任何独立于其大小和方向性的设备(或更精确地接收极化模式)。在这种情况下显示了过度增强的是一个有希望的解决方案,能够增加用户对测试设备EMC符合性的信心。本文还说明了作为测试条件的函数提取有效EUT的最小敏感性水平的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号