Purpose: Determination of lens opacity is important in aging glaucoma patients, because sensory testing may be influenced by increasing lens opacity. Purpose of this study was to measure lens opacity in normals and glaucoma patients using two different techniques, to compare both methods, and to correlate the results with contrast sensitivity testing. Methods: 94 glaucomatous eyes, 47 ocular hypertensive eyes, and 79 control eyes were studied using the following devices: opacity lens meter (OLM, objective back scatter method), stray light meter (SLM, subjective forward scatter using flicker light), and temporal contrast sensitivity (full-field flicker test). SLM results were separately analyzed at the lower and upper flicker disappearance. All subjects were younger than 66 years and had no significant cataracts. Results: In patients and in normal subjects OLM readings and SLM findings elicited at the upper disappearance point are significantly correlated with age and with each other (R>0.45, P<0.001), while SLM at the lower disappearance point shows no such correlation. In normals, but not in patients, SLM at the lower disappearance point is significantly correlated with temporal contrast sensitivity. Conclusions: Both devices can be used for quantifying lens opacity in glaucoma. SLM readings with increasing light intensity at the lower disappearance point seems to be more influenced by the individual flicker sensitivity than determination of the upper flicker disappearance. Therefore, using the SLM in glaucoma patients, the threshold measurements based on the upper disappearance of the flicker should be used instead of the suggested mean threshold measurements.
机译:目的:确定晶状体混浊度对衰老的青光眼患者很重要,因为感觉测试可能会受到晶状体混浊度增加的影响。这项研究的目的是使用两种不同的技术来测量正常人和青光眼患者的晶状体混浊度,比较两种方法,并将结果与​​对比敏感度测试进行关联。方法:使用以下设备研究了94例青光眼,47例高血压眼和79例对照眼:不透明性晶状体计(OLM,物镜后向散射法),杂散光度计(SLM,使用闪烁光的主观前向散射)和颞对比灵敏度(全场闪烁测试)。 SLM结果在上下闪烁消失处分别进行了分析。所有受试者均小于66岁,无明显的白内障。结果:在患者和正常受试者中,在消失高点引起的OLM读数和SLM结果与年龄以及彼此之间显着相关(R> 0.45,P <0.001),而在消失低点的SLM没有这种相关性。在正常人群中,但在患者中不是,消失点较低的SLM与时间对比敏感度显着相关。结论:这两种设备均可用于量化青光眼的晶状体混浊。在下消失点处光强度增加的SLM读数似乎比上闪烁消失的确定受个体闪烁敏感性的影响更大。因此,在青光眼患者中使用SLM时,应使用基于闪烁的上消失的阈值测量,而不是建议的平均阈值测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号