A large-area electro-thermal ageing test setup was developed and utilized to age several laboratory-scale biaxially oriented polypropylene (BOPP)-hydrophobic silica nanocomposite films. The films were aged in test capacitors with self-healing metallized film electrodes, which enabled the ageing test to continue beyond the first breakdowns. Eight different films were aged for 1000 hours under 100 V/μm DC stress at 75 °C, and large-area DC breakdown measurements, dielectric spectroscopy, gel permeation chromatography (GPC), differential scanning calorimetry (DSC) and dielectric spectroscopy were used to detect localized and bulk degradation after the ageing period. The effects of antioxidant contents, different PP grades and compounder screw speed were evaluated. Material characterization indicates no bulk degradation had occurred during ageing, which was associated with moderate temperature stress and inert nitrogen atmosphere. On the other hand, low-field breakdowns (weak points) were observed in all but two of the aged materials, indicating that ageing was dominated by localized degradation which may have introduced new breakdown mechanisms. Weak points were also measured in a similarly aged commercial capacitor-grade BOPP film aged at a lower field, supporting this conclusion. The importance of long-term characterization in material development is demonstrated, and it is shown that long-term properties of the evaluated nanocomposites were at least on the same level compared to neat BOPP films.
机译:开发了一个大面积的电热老化测试装置,并用于老化几个实验室规模的双轴取向聚丙烯(BOPP)-疏水性二氧化硅纳米复合膜。膜在具有自修复金属化膜电极的测试电容器中进行了老化,这使老化测试可以继续进行,直到第一次击穿为止。在100 V /μm直流电应力和75°C下,将八种不同的薄膜老化1000小时,并使用大面积直流击穿测量,介电谱,凝胶渗透色谱(GPC),差示扫描量热法(DSC)和介电谱检测老化后的局部和整体降解。评估了抗氧化剂含量,不同PP等级和混炼机螺杆转速的影响。材料表征表明,在老化过程中未发生整体降解,这与中等温度应力和惰性氮气氛有关。另一方面,除两种时效材料外,在所有时效材料中均观察到低场击穿(弱点),这表明时效主要由局部降解主导,这可能引入了新的击穿机理。还对在较低电场下老化的类似老化的商用电容器级BOPP薄膜进行了测量,证明了这一结论。证明了长期表征在材料开发中的重要性,并且表明与纯BOPP薄膜相比,所评估的纳米复合材料的长期特性至少处于相同水平。

著录项

  • 来源
  • 作者单位

    Tampere University of Technology, Department of Electrical Engineering, P.O. Box 692 FI-33101 Tampere, Finland;

    Tampere University of Technology, Department of Electrical Engineering, P.O. Box 692 FI-33101 Tampere, Finland;

    Tampere University of Technology, Department of Electrical Engineering, P.O. Box 692 FI-33101 Tampere, Finland;

    Borealis Polymers Oy, P.O. Box 330, FI-06101 Porvoo, Finland;

    VTT Technical Research Centre of Finland Ltd, P.O. Box 1300, FI-33101 Tampere, Finland;

    VTT Technical Research Centre of Finland Ltd, P.O. Box 1300, FI-33101 Tampere, Finland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Aging; Capacitors;

    机译:老化;电容器;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号