...
首页> 外文期刊>BMC Ophthalmology >Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study
【24h】

Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study

机译:OQAS和ITRACE分析仪微笑和FS-LASIK后光学质量的比较:一年的回顾性研究

获取原文
           

摘要

To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12?months after surgery. After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1?month were higher after FS-LASIK than SMILE. The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.
机译:比较小型切口仔细提取(微笑)和飞秒激光辅助激光器的校正效果和光学质量,用于高近视的原位角膜瘤(FS-LASIK)。 51近视眼睛微笑后的近视眼睛和49个高近视眼睛,回顾性FS-LASIK后,分为两组。 OQAS和ITRACE分析仪用于光学质量检验。分析了两组之间的球面等效物(SE),散光,未校正的远处视力(UDVA),斯特勒比比(SR),调制传递函数截止频率(MTF截止),对比进行了比较在手术前和在1,6和12岁以下?手术后的月份。操作结束后:(1)SE和散光下降,两组的UDVA显着增加,而UDVA在微笑后比FS-LASIK更好。 (2)微笑和FS-LASIK后,SR和MTF截止减少和OSI显着增加。微笑后Sr和MTF截止显着高于FS-LASIK。在微笑后OSI比FS-LASIK显着降低。 (3)总波前像差,总低阶波前像差,散焦和散光像差以及两组的三叶草像差显着减少。在FS-LASIK之后,高阶波前像差显着增加。两组球形和彗形像差显着增加。在fs-lasik比微笑之后,1个月的总高阶波前像差和昏迷像差更高。微笑后的光学质量下降,FS-LASIK下降。微笑优于FS-LASIK,以高近视的校正效果和光学质量。 OQAS和ITRACE分析仪的组合是在屈光外科后评估光学质量的有价值的互补测量。这是一个回顾性研究。本研究经湘雅医院伦理委员会批准,IRB批准号是201612074。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号