Background Serum creatinine is a widely used biomarker for evaluating renal function. Sarcosine oxidase enzymatic (SOE) analysis is currently the most widely used method for the detection of creatinine. This method was negatively interfered with by calcium dobesilate, causing pseudo-reduced results. The aim of this study was to explore a new method to alleviate the negative interference of this drug on creatinine detection. Method We formulated eight drug concentrations and 12 creatinine concentrations from serum. The SOE method, the new method, and the Jaffe method were used for detection in five systems. Creatinine biases were analyzed under the conditions with or without the interference of calcium dobesilate, at consistent or inconsistent creatinine concentrations. Creatinine concentrations were also analyzed at three medical decision levels (MDLs). Results Calcium dobesilate had negative interference in creatinine SOE analysis. With the increase in calcium dobesilate concentrations, the negative bias increases. The new BG method showed an anti-negative interference effect. In the Roche system, the BG method reduced the negative bias from ?71.11% to ?16.7%. In the Abbott system, bias was reduced from ?45.15% to ?2.74%. In the Beckman system, the bias was reduced from ?65.36% to ?7.58%. In the Siemens system, the bias was reduced from ?58.62% to ?7.58%. In the Mindray system, the bias was reduced from ?36.29% to ?6.84%. Conclusion The new method alleviated the negative interference of calcium dobesilate in creatinine SOE detection. The negative bias could be reduced from ?60% or ?70% to less than ?20%.
机译:背景技术血清肌酐是一种广泛使用的生物标志物,用于评估肾功能。 Sarcosine氧化酶酶促(SOE)分析目前是最广泛使用的肌酸酐的方法。这种方法被钙酸钙受到防粘,导致伪减少的结果。本研究的目的是探讨缓解该药物对肌酐检测的负干扰的新方法。方法我们配制了血清的八种药物浓度和12种肌酐浓度。使用SOE方法,新方法和jaffe方法用于检测五种系统。在具有或不干扰钙含量的情况下,在一致或不一致的肌酐浓度下分析肌酐偏见。还在三个医学决策水平(MDL)分析肌酐浓度。结果钙酸钙对肌酐SOE分析产生负干扰。随着钙的钙浓度的增加,负偏差增加。新的BG方法显示出抗负干扰效果。在罗氏系统中,BG方法将负偏差减少71.11%至16.7%。在Abbott系统中,偏差从?45.15%降低到2.74%。在Beckman系统中,偏差从?65.36%减少到7.58%。在西门子系统中,偏差从Δ58.62%减少到7.58%。在MindRay系统中,偏差从?36.29%减少到6.84%。结论新方法缓解了肌酐SOE检测中钙的负干扰。负偏差可以减少60%或70%至少于20%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号