Spinal stiffness assessment has the potential to become an important clinical measure. Various spinal stiffness-testing devices are available to help researchers objectively evaluate the spine and patient complaints. One of these is VerteTrack, a device capable of measuring posteroanterior displacement values over an entire spinal region. This study aimed to develop a best-practice protocol for evaluating spinal stiffness in human participants using VerteTrack. Twenty-five individuals with research experience in measuring spinal stiffness, or who were trained in spinal stiffness measurement using the VerteTrack device, were invited to participate in this 3-Round Delphi study. Answers to open-ended questions in Round 1 were thematically analyzed and translated into statements about VerteTrack operation for spinal stiffness measurements. Participants then rated their level of agreement with these statements using a 5-point Likert scale in Rounds 2 and 3. A descriptive statistical analysis was performed. Consensus was achieved when at least 70% of the participants either strongly agreed, agreed, (or strongly disagreed, disagreed) to include a statement in the final protocol. Twenty participants completed Round 1 (80%). All these participants completed Rounds 2 and 3. In total, the pre-defined consensus threshold was reached for 67.2% (123/183) of statements after three rounds of surveys. From this, a best-practice protocol was created. Using a Delphi approach, a consensus-based protocol for measuring spinal stiffness using the VerteTrack was developed. This standard protocol will help to improve the accuracy, efficiency, and safety of spinal stiffness measurements, facilitate the training of new operators, increase consistency of these measurements in multicenter studies, and provide the synergy and potential for data comparison between spine studies internationally. Although specific to VerteTrack, the resulting standard protocol could be modified for use with other devices designed to collect spinal stiffness measures.
机译:脊柱僵硬评估有可能成为一个重要的临床措施。各种脊柱刚度测试设备可用于帮助研究人员客观地评估脊柱和患者投诉。其中之一是vertetrack,一种能够在整个脊柱区域测量后剖位位移值的装置。本研究旨在开发使用VERTETRACK评估人类参与者脊柱刚度的最佳实践方案。邀请使用VERTETRACK装置测量脊柱僵硬度或者在脊柱刚度测量中培训的二十五个人,参与了这项3次德尔福研究。主题分析了第1轮开放问题的答案,并转化为关于脊柱刚度测量的vertetrack操作的陈述。然后,参与者将他们的协议级别与这些陈述的达成水平,使用5点李克特秤在第2轮和3中进行了描述性统计分析。当至少70%的参与者强烈同意,同意(或强烈不同意,不同意)时,达成共识,以便在最终议定书中列入一份声明。二十名参与者完成第1轮(80%)。所有这些参与者完成了第2轮和3.总共达到了预定的共识阈值,在三轮调查后达到了67.2%(123/183)陈述。由此,创建了一个最佳实践协议。使用Delphi方法,开发了一种用于使用vertetrack测量脊柱刚度的基于共识的协议。本标准协议将有助于提高脊柱僵硬测量的准确性,效率和安全性,促进新运营商的培训,增加了多中心研究中这些测量的一致性,并提供了国际上脊柱研究之间的数据比较的协同作用和潜力。虽然特定于vertRack,但是可以修改所得到的标准方案,以便与旨在收集脊柱刚度措施的其他装置使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号