The Effect of Outdoor Temperature on the Performance of a Split-Unit Type Air Conditioner Using R22 Refrigerant

机译:室外温度对使用R22制冷剂的分裂单元型空调性能的影响

获取原文
           

摘要

To maintain the temperature setup on an air conditioner, the compressor will use more or less energy based on the outdoor temperature. Therefore, there is a need to understand the performance of the air conditioner if the outdoor temperature is varied. In this research, a used small capacity split-unit air conditioner using R-22 refrigerant is used to study the effect of outdoor temperature on the performance of the air conditioner. From the results, it can be understood that lower outdoor temperature requires less work from the compressor. The cooling capacity and coefficient of performance drop as the outdoor temperature increases.
机译:为了将温度设定保持在空调上,压缩机将基于室外温度使用或多或少的能量。因此,如果室外温度变化,需要了解空调的性能。在本研究中,使用使用R-22制冷剂的使用的小容量分体式空调器来研究室外温度对空调性能的影响。从结果中,可以理解,较低的室外温度需要较少的压缩机工作。随着室外温度的增加,降温能力和性能下降系数。