The aim of this study was to evaluate the clinical performance of AdvanSure GenoBlot assay using nontuberculous mycobacteria (NTM) isolates and clinical specimens. A total of 136 NTM isolates and 176 clinical specimens were used in this study. AdvanSure Mycobacteria GenoBlot assay was performed according to the manufacturer’s instructions. We compared the results with those of 16S rRNA and rpoB genes sequencing. Out of the 136 NTM isolates, 111 (81.6%) were correctly identified to the species level using the GenoBlot assay. The final concordance rate was 89.7% (122/136), including 11 Mycobacterium genus positive control (GPC) results for uncommon NTM. The most common NTM, M. avium, M. fortuitum, M. gordonae, M. intracellulare, M. chelonae, M. abscessus, and M. kansasii, were correctly identified using the GenoBlot assay. For 176 organisms in clinical specimens, 117 were identified to the species level, including single species for 111 specimens and two species for 6 specimens. The final detection and identification rates for clinical specimens were 94.9% and 66.5%, respectively. The AdvanSure GenoBlot assay performs well in identifying the most common NTM, and would be useful in a clinical laboratory.
机译:本研究的目的是评估使用不泛骨分枝杆菌(NTM)分离物和临床标本的Advansure Genoblot测定的临床表现。本研究共使用136个NTM分离物和176个临床标本。 Admansure Cocobacteria Genoblot测定根据制造商的说明进行。我们将结果与16S RRNA和RPOB基因测序进行比较。在136个NTM分离物中,使用Genoblot测定正确地将111(81.6%)正确鉴定到物种水平。最终的一致性率为89.7%(122/136),其中阳性对照(GPC)的11个阳性对照(GPC)结果罕见。使用Genoblot测定,正确鉴定使用Genoblot测定,正确鉴定了最常见的NTM,M.Fortup,M.Gortucum,M.Gortacellare,M. Chelonae,M.横坐期和M. kansasii。对于临床标本中的176个生物,将117种鉴定到物种水平,包括111个标本的单一物种和6种样品的两种物种。临床标本的最终检测和识别率分别为94.9%和66.5%。 Advansure Genoblot测定在鉴定最常见的NTM时表现良好,并且在临床实验室中可用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号