A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept

机译:IGRT锥形CT的投影质量驱动管电流调制方法:概念证明

获取原文
   

获取外文期刊封面封底 >>

       

摘要

To develop a projection quality-driven tube current modulation method in cone-beam computed tomography for image-guided radiotherapy based on the prior attenuation information obtained by the planning computed tomography and then evaluate its effect on a reduction in the imaging dose. The QCKV-1 phantom with different thicknesses (0-400 mm) of solid water upon it was used to simulate different attenuation (μ). Projections were acquired with a series of tube current-exposure time product (mAs) settings, and a 2-dimensional contrast to noise ratio was analyzed for each projection to create a lookup table of mAs versus 2-dimensional contrast to noise ratio, μ. Before a patient underwent computed tomography, the maximum attenuation [Formula: see text] within the 95% range of each projection angle (θ) was estimated according to the planning computed tomography images. Then, a desired 2-dimensional contrast to noise ratio value was selected, and the mAs setting at θ was calculated with the lookup table of mAs versus 2-dimensional contrast to noise ratio,[Formula: see text]. Three-dimensional cone-beam computed tomography images were reconstructed using the projections acquired with the selected mAs. The imaging dose was evaluated with a polymethyl methacrylate dosimetry phantom in terms of volume computed tomography dose index. Image quality was analyzed using a Catphan 503 phantom with an oval body annulus and a pelvis phantom. For the Catphan 503 phantom, the cone-beam computed tomography image obtained by the projection quality-driven tube current modulation method had a similar quality to that of conventional cone-beam computed tomography . However, the proposed method could reduce the imaging dose by 16% to 33% to achieve an equivalent contrast to noise ratio value. For the pelvis phantom, the structural similarity index was 0.992 with a dose reduction of 39.7% for the projection quality-driven tube current modulation method. The proposed method could reduce the additional dose to the patient while not degrading the image quality for cone-beam computed tomography. The projection quality-driven tube current modulation method could be especially beneficial to patients who undergo cone-beam computed tomography frequently during a treatment course.
机译:基于规划计算机断层扫描获得的先前衰减信息,在锥形光束计算机断层扫描中开发锥形光束计算机断层扫描的投影质量驱动管电流调制方法,然后评估其对成像剂量减少的影响。在其上具有不同厚度(0-400mm)的QCKV-1幻影,用于模拟不同的衰减(μ)。通过一系列管电流曝光时间产品(MAS)设置获得投影,并分析了与噪声比的二维对比度,以创建MAS的查找表与二维对比与噪声比,μ。在患者接受计算机断层扫描之前,根据规划计算的断层摄影图像估计,在每个投影角度(θ)的95%范围内的最大衰减[公式:参见文本]。然后,选择与噪声比值值的期望的二维对比度,并且用MAS的查找表与噪声比对比的查找表来计算θ处的MAS设置,[公式:参见文本]。使用用所选MAS获取的投影来重建三维锥形束计算机断层摄影图像。在体积计算断层摄影剂量指数方面,用聚甲基丙烯酸甲基丙烯酸甲酯剂量测定模型评价成像剂量。使用Catphan 503幻影分析图像质量,具有椭圆体环和骨盆幻影。对于Catphan 503幻影,通过投影质量驱动的管电流调制方法获得的锥形光束计算机断层摄影图像具有与传统锥形光束计算机断层扫描的质量相似。然而,所提出的方法可以将成像剂量减少16%至33%,以达到与噪声比值的等同对比。对于骨盆幻影,结构相似性指数为0.992,减少投影质量驱动管电流调制方法的剂量减少39.7%。所提出的方法可以减少患者的额外剂量,同时不会降低锥形束计算机断层扫描的图像质量。投影质量驱动的管电流调制方法可能对经常在治疗过程中经常经常接受锥形束的患者尤为有益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号