Steel monopiles, jackets requiring four steel pinpiles, and gravity-based foundations were applied in offshore wind farms in the Belgian part of the North Sea. This paper compares the underwater noise generated during the piling activities of steel monopiles at the Belwind wind farm (Blighbank) with that of jacket pinpiles at the C-Power project (Thorntonbank). Underwater noise was measured at various distances from the pile driving location. The underwater noise was quantified by its zero to peak sound pressure level (Lz−p), unweighted sound exposure level (SEL), cumulative SEL, and 1/3 octave spectra. No significant differences inLz−pcould be demonstrated (monopileLz−p: 179–194 dB re 1 μPa, jacketLz−p: 172–189 dB re 1 μPa). SEL showed no statistical difference between monopile and jacket and varied between 145 and 168 dB re 1 μPa2s. Furthermore, near identical spectra were measured for both types of piling. Piling of the jacket pinpiles took, however, about 2.5 times the time of the monopile. When standardised to megawatt installed per foundation both types of piling scored near equally. As an illustration, the radius of major behavioural disturbance (Lp−p=155 dB re 1 μPa) in the harbour porpoisePhocoena phocoenawas estimated by a model at 16 km for monopiles and at 8 km for jacket.
机译:在北海比利时部分的海上风电场,需要四个钢总针钳的钢幂,需要重力的基础。本文比较了在C-Power Project(Thorntonbank)的夹克风电场(Blighbank)在Belwind风电场(Blighbank)的钢幂块的打桩活动中产生的水下噪声。从桩驱动位置的各个距离处测量水下噪声。通过其零峰值对峰值声压(LZ-P),未加权的声曝光水平(SEL),累积SEL和1/3八度音频光谱量量化了水下噪声。没有显着的差异Inlz-PCOND(MonopiLelz-P:179-194dBRe1μPa,jacketlz-p:172-189dB Re1μPa)。 SEL在单披上和夹套之间没有统计差异,在145和168dB的RE1μPA2之间变化。此外,测量近相同的光谱,用于两种类型的堆积。然而,夹克针刺的堆积率约为纪念碑的时间约为2.5倍。当标准化到兆瓦安装的每件地区安装时,两种类型的打桩平均得分。作为一名插图,在港口Porpoisephocoena的主要行为扰动(LP-P = 155dB RE1μPA)的半径由一个型号估计为16公里的Monopiles,夹克8公里。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号