...
首页> 外文期刊>Radiation oncology >The diagnostic value of quantitative analysis of ASL, DSC-MRI and DKI in the grading of cerebral gliomas: a meta-analysis
【24h】

The diagnostic value of quantitative analysis of ASL, DSC-MRI and DKI in the grading of cerebral gliomas: a meta-analysis

机译:ASL,DSC-MRI和DKI定量分析在脑胶质瘤分级中的定量分析诊断值:META分析

获取原文
   

获取外文期刊封面封底 >>

       

摘要

To perform quantitative analysis on the efficacy of using relative cerebral blood flow (rCBF) in arterial spin labeling (ASL), relative cerebral blood volume (rCBV) in dynamic magnetic sensitivity contrast-enhanced magnetic resonance imaging (DSC-MRI), and mean kurtosis (MK) in diffusion kurtosis imaging (DKI) to grade cerebral gliomas. Literature regarding ASL, DSC-MRI, or DKI in cerebral gliomas grading in both English and Chinese were searched from PubMed, Embase, Web of Science, CBM, China National Knowledge Infrastructure (CNKI), and Wanfang Database as of 2019. A meta-analysis was performed to evaluate the efficacy of ASL, DSC-MRI, and DKI in the grading of cerebral gliomas. A total of 54 articles (11 in Chinese and 43 in English) were included. Three quantitative parameters in the grading of cerebral gliomas, rCBF in ASL, rCBV in DSC-MRI, and MK in DKI had the pooled sensitivity of 0.88 [95% CI (0.83,0.92)], 0.92 [95% CI (0.83,0.96)], 0.88 [95% CI (0.82,0.92)], and the pooled specificity of 0.91 [95% CI (0.84,0.94)], 0.81 [95% CI (0.73,0.88)], 0.86 [95% CI (0.78,0.91)] respectively. The pooled area under the curve (AUC) were 0.95 [95% CI (0.93,0.97)], 0.91 [95% CI (0.89,0.94)], 0.93 [95% CI (0.91,0.95)] respectively. Quantitative parameters rCBF, rCBV and MK have high diagnostic accuracy for preoperative grading of cerebral gliomas.
机译:对动态磁敏灵敏度对比增强磁共振成像(DSC-MRI)中的相对脑血流(ASL)中使用相对脑血流量(RCBF),相对脑血量(RCBV)的测量分析,相对脑血容量(RCBV),以及平均峰度(MK)在扩散Kurtosis成像(DKI)到级脑胶质瘤。关于ASL,DSC-MRI或DKI的文献,在英语和中文中,从Pubmed,Embase,Science,CBM,中国国家知识基础设施(CNKI)和Wanfang数据库中搜索了英语和中国人的脑胶质瘤中的脑胶质瘤中的DKI。一个Meta-进行分析以评估ASL,DSC-MRI和DKI在脑胶质瘤分级中的功效。共有54篇文章(英文中有11条)。在脑胶质瘤的分级中,ASL中的RCBF,DSC-MRI中的RCBF和DKI中的MK中的三种定量参数具有0.88 [95%CI(0.83,0.92)],0.92 [95%CI(0.83,0.96(0.83,0.96)的汇总灵敏度。 )],0.88 [95%CI(0.82,0.92)],汇集特异性为0.91 [95%Ci(0.84,0.94)],0.81 [95%Ci(0.73,0.88)],0.86 [95%Ci( 0.78,0.91)分别。曲线(AUC)下的汇集区域分别为0.95 [95%CI(0.93,0.97)],0.91 [95%CI(0.89,0.94)],分别为0.93 [95%CI(0.91,0.95)]。定量参数RCBF,RCBV和MK具有高诊断准确性,用于脑胶质瘤的术前分级。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号