...
首页> 外文期刊>International Journal of Environmental Research and Public Health >Correlation and Reliability Analyses among the Upper Cervical Rotation-Flexion Test, Upper Cervical Flexion-Extension Test, and Upper Cervical Flexion Angle Measurement Using Radiography
【24h】

Correlation and Reliability Analyses among the Upper Cervical Rotation-Flexion Test, Upper Cervical Flexion-Extension Test, and Upper Cervical Flexion Angle Measurement Using Radiography

机译:上颈旋转屈曲试验,上颈屈曲 - 延伸试验和射线照相上颈椎屈曲角度测量的相关性和可靠性分析

获取原文
           

摘要

(1) Background: The cervical rotation-flexion test is one method of measuring the range of motion of the upper cervical spine; however, this test has not been investigated in detail. The aim of this study was to investigate the reliability and concurrent validity of the upper cervical rotation-flexion test. (2) Methods: Twenty-five healthy individuals (13 women and 12 men) participated in this study. The participants underwent radiography, the upper cervical flexion-extension test, and the upper cervical rotation-flexion test in a sitting position while wearing a cervical goniometer to measure the upper cervical flexion angle. Three experienced physical therapists administered the upper cervical rotation-flexion test using the cervical device, twice for each participant. Inter-rater and intra-rater reliabilities were evaluated using the intraclass correlation coefficient (95% confidence interval). (3) Results: The inter-rater and intra-rater reliability values of the total scores were excellent. The results of the upper cervical rotation-flexion test significantly correlated with those of the radiographic evaluation of the upper cervical flexion angle ( r = 0.80, p 0.001) and those of the upper cervical flexion-extension test ( r = 0.77, p 0.001). Significant correlations among the three test results were observed. (4) Conclusions: The findings of this study suggest that the upper cervical rotation-flexion test is meaningful for independently measuring the upper cervical flexion angle.
机译:(1)背景:颈椎旋转屈曲试验是测量上颈椎运动范围的方法;但是,该测试尚未详细研究。本研究的目的是探讨上颈旋转屈曲测试的可靠性和并发有效性。 (2)方法:二十五个健康个体(13名妇女和12名男子)参加了这项研究。参与者接受射击照相,上颈部屈曲 - 延伸试验,以及在坐姿的同时在坐姿的上上颈旋转弯曲试验,以测量上颈部屈曲角度。三种经验丰富的物理治疗师使用宫颈器件给上颈旋转屈曲试验,每次参与者两次。使用腹部相关系数(95%置信区间)评估帧间间和帧内可靠性。 (3)结果:帧内间分数的帧间间和帧内可靠性值优异。上部颈椎旋转屈曲试验的结果与上颈椎屈曲角度(r = 0.80,p <0.001)和上宫颈屈曲 - 延伸试验(r = 0.77,p <)的放射线评估结果显着相关0.001)。观察到三种测试结果之间的显着相关性。 (4)结论:本研究的结果表明,上颈旋转 - 屈曲试验对于独立测量上部颈椎屈曲角度是有意义的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号