首页> 外文期刊>Case Reports in Orthopedics >Posterior Dislocation of the Hinge-Post Extension in a Rotating Hinge Total Knee Prosthesis
【24h】

Posterior Dislocation of the Hinge-Post Extension in a Rotating Hinge Total Knee Prosthesis

机译:旋转铰链总膝关节假体的铰链柱延伸的后脱位

获取原文
           

摘要

The rotating hinge knee prosthesis is a popular intervention in patients lacking stability with highly constrained total knee arthroplasty. Despite improvements in design, nonmechanical and mechanical complications continue to be a problem. Dislocation of the hinge has been widely described, mainly due to the component fracture. Few reports describe isolated dislocation of the rotating stem. We report a case of isolated disengagement of the rotating hinge mechanism, due to severe flexion gap imbalance, leading to subsequent posterior dislocation of the hinge and anterior knee dislocation, in a patient with a history of multiple total knee arthroplasty revisions. This case suggests the importance of the soft tissue balancing, the adequate patellar tracking, and use of a long cylindrical, minimally tapered rotating stem in hinge arthroplasty to minimize hinge dislocation.
机译:旋转铰链膝关节假体是患者缺乏稳定性的患者的普遍干预,具有高度约束的总膝关节置换术。尽管设计有所改善,但非机械和机械并发症仍然是一个问题。铰链的脱位已被广泛描述,主要是由于组分骨折。很少有报道描述旋转杆的隔离位错。我们报告了旋转铰链机构的隔离脱离的情况,由于严重的屈曲间隙不平衡,导致随后的铰链和前膝脱位的后偏见,在具有多个全膝关节成形术术史的患者中。这种情况表明软组织平衡,足够的髌骨跟踪和使用长圆柱形,微小锥形旋转杆在铰链关节成形术中的重要性,以最小化铰链位错。