摘要

Aseptic loosening remains a major problem for uncemented femoral components in primary total hip arthroplasty (THA). Ideally, bone adaptation after THA manifests minimally and local bone density reduction is widely avoided. Different design features may help to approximate initial, post-THA bone strain to levels pre-THA. Strain-shielding effects of different SP-CL stem design features are systematically analyzed and compared to CLS Spotorno and CORAIL using finite element models and physiological musculoskeletal loading conditions. All designs show substantial proximal strain-shielding: 50% reduced medial surface strain, 40-50% reduction at lateral surface, 120?μm/m root mean square error (RMSE) compared to intact bone in Gruen zone 1 and 60?μm/m RMSE in Gruen zones 2, 6, and 7. Geometrical changes (ribs, grooves, cross sections, stem length, anatomic curvature) have a considerable effect on strain-shielding; up to 20%. Combinations of reduced stem stiffness with larger proximal contact area (anatomically curved, grooves) lead to less strain-shielding compared to clinically established implant designs. We found that only the combination of a structurally flexible stem with anatomical curvature and grooves improves strain-shielding compared to other designs. The clinical implications in vivo of this initial strain-shielding difference are currently under evaluation in an ongoing clinical analysis.
机译:无菌性松动仍然是原发性全髋关节置换术(THA)中股骨成分未粘连的主要问题。理想情况下,THA后的骨适应性最小,并且广泛避免局部骨密度降低。不同的设计特征可能有助于将初始,THA后的骨应变近似于THA之前的水平。系统地分析了不同SP-CL杆设计特征的应变屏蔽效果,并使用有限元模型和生理性骨骼肌肉加载条件将其与CLS Spotorno和CORAIL进行了比较。所有设计均显示出充分的近端应变屏蔽:与Gruen 1区的完整骨骼和> 60?的骨骼相比,内侧表面的应变降低了50%,侧面的应力降低了40-50%,> 120μm/ m的均方根误差(RMSE)。格伦第2、6和7区的μm/ m RMSE。几何变化(肋,槽,横截面,茎长,解剖曲率)对应变屏蔽有很大影响。高达20%。与临床上确定的植入物设计相比,降低的茎杆刚度和更大的近端接触面积(解剖学弯曲,凹槽)相结合,可减少应变屏蔽。我们发现,与其他设计相比,只有具有解剖学曲率和凹槽的结构灵活的茎杆的组合才能改善应变屏蔽。目前,这种初始的应变屏蔽差异在体内的临床意义正在一项正在进行的临床分析中进行评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号