...
首页> 外文期刊>Journal of Clinical and Diagnostic Research >Scanning Electron Microscopic Evaluation of Root Canal Surfaces Prepared with LightSpeed & Endowave rotary system
【24h】

Scanning Electron Microscopic Evaluation of Root Canal Surfaces Prepared with LightSpeed & Endowave rotary system

机译:用LightSpeed和Endowave旋转系统制备的根管表面的扫描电子显微镜评估

获取原文

摘要

Background and Objectives: The purpose of this in vitro study was to evaluate and compare the cleaning efficiency on root canal surfaces prepared with LightSpeed and Endowave rotary instruments.Materials and Methods: A total of 30 freshly extracted human mandibular premolars were subjected for the study. They were divided into two groups, each group consisting of 15 teeth. Group 1: The canals were prepared with LightSpeed system. Group 2: Endowave rotary system. All the groups were prepared according to manufacturer?s recommendation, using 5.25% sodium hypochlorite and 17% EDTA (dent wash, prime dent) alternately as an irrigants. Crowns of each tooth were removed with diamond disks at the level of cement enamel junction. Canal length was determined by placing a size 10 K-file. The working length was 0.5 mm short of canal length. Two longitudinal grooves were prepared on the lingual and buccal surfaces of each root to facilitate vertical splitting with a chisel after canal instrumentation. The sections were then observed under SEM for presence or absence of debris and smear layer and the photographs were taken at coronal, middle and apical 1/3 with a magnification of 200 X and 1000X respectively. The scores recorded were statistically analysed using one-way-ANOVA and Mann- Whitney test.Results: There was statistically significant difference between two groups. All groups resulted in significantly more debris and smear layer in the apical 1/3 of the canal, compared to coronal and middle 1/3 (p, <0.01).Interpretation and Conclusion: The study demonstrated that, LightSpeed instrumentation removed debris and smear layer more effectively on root canal surface than compared to Endowave instrument.
机译:背景与目的:这项体外研究的目的是评估和比较使用LightSpeed和Endowave旋转器械制备的根管表面的清洁效率。材料与方法:总共对30个新鲜提取的人类下颌前磨牙进行了研究。他们分为两组,每组15颗牙齿。第一组:使用LightSpeed系统准备运河。第2组:Endowave旋转系统。所有组均根据制造商的建议进行准备,交替使用5.25%的次氯酸钠和17%的EDTA(牙膏,初生牙膏)作为冲洗液。在水泥搪瓷连接处用金刚石磨片去除每个牙齿的冠状。通过放置大小为10 K的锉刀确定运河长度。工作长度比根管长度短0.5毫米。在每个根的舌侧和颊侧表面上准备了两个纵向凹槽,以利于在根管器械安装后用凿子进行垂直劈裂。然后在SEM下观察切片,看是否存在碎片和涂片层,并分别以200 X和1000 X的放大倍数在冠状,中部和顶端1/3处拍摄照片。记录的得分采用单因素方差分析和Mann-Whitney检验进行统计分析。结果:两组之间存在统计学差异。与冠状和中间1/3相比,所有组在根管的1/3处产生的碎屑和涂片层明显更多(p,<0.01)。解释和结论:研究表明,LightSpeed仪器去除了碎屑和涂片。与Endowave器械相比,在根管表面更有效地分层。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号