As part of a clinical investigation evaluating the efficacy of intrapartum antigen detection for screening for heavy vaginal colonization with group B streptococci (GBS), we compared the performance of modified Bactigen and Directigen GBS latex particle agglutination (LPA) kits. Paired vaginal swabs obtained from women in labor were rapidly transported to the laboratory and used for culturing (both swabs) and LPA testing (one swab by each method). GBS growth was estimated semiquantitatively and further designated as light or heavy growth. Performance specifications for each method were determined by comparing LPA and culture results from the same swab. A total of 4,251 paired swabs were evaluated during the study period. The performance specifications for detecting GBS growth of any degree for Bactigen and Directigen, respectively, were as follows: sensitivity, 20 and 24%; specificity, 99 and 99%. The performance specifications for heavy colonization for Bactigen and Directigen, respectively, were as follows: sensitivity, 57 and 62%; specificity, 99 and 99%. Neither LPA kit was a sensitive indicator of vaginal colonization with GBS or neonatal infection.
机译:作为评估产时抗原检测以B组链球菌(GBS)筛查重度阴道菌落的功效的临床研究的一部分,我们比较了改良的细菌原和Directigen GBS乳胶颗粒凝集(LPA)试剂盒的性能。从分娩妇女那里获得的成对的阴道拭子被迅速运送到实验室,并用于培养(两种拭子)和LPA测试(每种方法一种拭子)。 GBS的增长是半定量估计的,并进一步指定为轻度或重度增长。通过比较LPA和同一拭子的培养结果来确定每种方法的性能指标。在研究期间,总共对4,251对棉签进行了评估。分别检测细菌和Directigen的任何程度的GBS增长的性能规格如下:灵敏度分别为20%和24%;特异性分别为99%和99%。细菌原和Directigen的重定殖性能规格分别如下:灵敏度分别为57%和62%。特异性分别为99%和99%。 LPA试剂盒都不是GBS或新生儿感染阴道定植的敏感指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号