This report describes a new, rapid, sensitive, and quantitative method for the detection of immune complexes, endotoxins, and other complement activating materials in patients sera utilizing the ability of these substances to react with isolated C1q. The procedure is based on the inhibition of radiolabeled C1q binding to sensitized sheep erythrocytes by C1q-reactive substances in pathological sera. The C1q deviation test may be performed on 50 mu1 of serum, using 1 mug of radiolabeled C1q per sample. The procedure may be completed in 1.5-2 h, it is capable of detecting 5 mug of aggregated human IgG per ml of serum, and its coefficient of variation is 4.2%. Application of the test to the study of 193 sera from 43 patients with Dengue hemorrhagic fever showed a positive correlation between degree of C1q deviation and severity of disease.
机译:本报告介绍了一种新的,快速,灵敏和定量的方法,可利用这些物质与分离的C1q反应的能力来检测患者血清中的免疫复合物,内毒素和其他补体激活物质。该程序基于病理血清中C1q反应性物质抑制放射性标记的C1q与致敏绵羊红细胞的结合。 C1q偏差测试可以在50μl血清上进行,每个样品使用1杯放射性标记的C1q。该过程可在1.5至2小时内完成,每毫升血清可检测5杯聚集的人IgG,变异系数为4.2%。该试验在43例登革出血热患者的193血清研究中的应用表明C1q偏离程度与疾病严重程度呈正相关。