The Computational Model of the Peak Regulation Capacity of Cogeneration Units and Its Application

机译:热电联产机组调峰能力的计算模型及其应用

获取原文
           

摘要

Studying the peak regulation capacity of cogeneration units is of positive significance to improve the power grid dispatching capacity and promote the new energy source. In order to scientifically calculate the peak shaving capacity of a cogeneration unit, the variable condition calculation model is built up based on the theory of equivalent heat drop, and the load constraint model is also established according to the actual situation, on this basis the complete computational model of the peak regulation capacity of cogeneration units is obtained. Based on a 350MW cogeneration unit in Shandong province, the peak regulation capacity calculation is carried out, and the factors affecting the peak regulation capacity of the unit are analyzed. Compared with the experimental results, the calculation model of the peak regulation capacity in this paper shows a high precision, and can be used to predict the peak regulation capacity of the cogeneration units in different working conditions.
机译:研究热电联产机组的调峰能力对提高电网调度能力和推广新能源具有积极意义。为了科学地计算热电联产机组的削峰能力,基于当量热降的理论建立了变工况计算模型,并根据实际情况建立了负荷约束模型,在此基础上完成了获得了热电联产机组调峰能力的计算模型。以山东某350MW热电联产机组为例,进行了调峰能力的计算,分析了影响该机组调峰能力的因素。与实验结果相比,本文调峰能力的计算模型具有较高的精度,可用于预测不同工况下热电联产机组的调峰能力。