Background: Increased α-fetoprotein (AFP) in adult plasma is considered an early indication of hepatocellular carcinoma and teratoblastoma. The aim of this study was to develop a rapid method to measure AFP in human serum by use of a direct immunosensor based on a quartz crystal microbalance (QCM).Methods: A self-assembled monolayer prepared by the cystamine method was applied to immobilize anti-AFP monoclonal antibodies on the gold surface of a quartz crystal. The frequency shifts of the QCM were measured and related to AFP concentrations. The piazoimmunosensor used no labeled reagent and no pretreatment of samples.Results: Ten cycles of measurements could be performed on the gold surface of the same crystal regenerated with a solution of glycine-HCl. A linear relationship existed between the frequency shifts (Hz) and the log values of AFP concentrations from 0.1 to 100 μg/L in buffer and human serum. When used for 15 days, the frequency shifts were all 95% of those on the response at the first day. The regression equation was y = 1.03 x ? 0.06 ( S y|x = 3.92; r = 0.9987) for this QCM method and RIA in 29 clinical human serum samples.Conclusions: The QCM sensor can measure AFP in buffer and human serum and offers advantages of high specificity, reusability, low detection limit, no label or sample pretreatment, and low sample requirement. The assay format of the immunosensor was more rapid and simpler than conventional methods.
机译:背景:成人血浆中的甲胎蛋白(AFP)升高被认为是肝细胞癌和成胶质细胞瘤的早期迹象。这项研究的目的是开发一种基于石英晶体微量天平(QCM)的直接免疫传感器快速测定人血清中AFP的方法。方法:采用胱胺法制备的自组装单层膜固定化抗血清-AFP单克隆抗体在石英晶体的金表面。测量了QCM的频移并与AFP浓度有关。结果表明:用甘氨酸-盐酸溶液再生的同一晶体的金表面可以进行十个循环的测量。在缓冲液和人血清中,频率偏移(Hz)与AFP浓度的log值从0.1至100μg/ L之间存在线性关系。当使用15天时,频移均大于第一天响应中的频移的95%。回归方程为y = 1.03 x?该QCM方法和RIA在29个临床人血清样品中为0.06(S y | x = 3.92; r = 0.9987)。结论:QCM传感器可以测量缓冲液和人血清中的AFP,具有高特异性,可重复使用性,低检测的优势极限,无标签或样品预处理,且样品要求低。免疫传感器的测定形式比常规方法更快,更简单。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号