...
首页> 外文期刊>Journal of Medical Physics/Association of Medical Physicists of India >Influence of increment of gantry angle and number of arcs on esophageal volumetric modulated arc therapy planning in Monaco planning system: A planning study
【24h】

Influence of increment of gantry angle and number of arcs on esophageal volumetric modulated arc therapy planning in Monaco planning system: A planning study

机译:摩纳哥计划系统中龙门架角度增量和弧数对食管容积调制式弧光治疗计划的影响:一项计划研究

获取原文
           

摘要

The objective of this study was to analyze the influence of the increment of gantry angle and the number of arcs on esophageal volumetric modulated arc therapy plan. All plans were done in Monaco planning system for Elekta Synergy linear accelerator with 80 multileaf collimator (MLC). Volumetric modulated arc therapy (VMAT) plans were done with different increment of gantry angle like 15°, 20°, 30° and 40°. The remaining parameters were similar for all the plans. The results were compared. To compare the plan quality with number of arcs, VMAT plans were done with single and dual arc with increment of gantry angle of 20°. The dose to gross tumor volume (GTV) for 60 Gy and planning target volume (PTV) for 48 Gy was compared. The dosimetric parameters D98%, D95%, D50% and Dmax of GTV were analyzed. The homogeneity index (HI) and conformity index (CI) of GTV were studied and the dose to 98% and 95% of PTV was analyzed. Maximum dose to spinal cord and planning risk volume of cord (PRV cord) was compared. The Volume of lung receiving 10 Gy, 20 Gy and mean dose was analyzed. The volume of heart receiving 30 Gy and 45 Gy was compared. The volume of normal tissue receiving greater than 2 Gy and 5 Gy was compared. The number of monitor units (MU) required to deliver the plans were compared. The plan with larger increment of gantry angle proved to be superior to smaller increment of gantry angle plans in terms of dose coverage, HI, CI and normal tissue sparing. The number of arcs did not make any difference in the quality of the plan.Keywords: Esophagus cases, increment of gantry angle, number of arcs, VMAT
机译:这项研究的目的是分析机架角度的增加和弧数对食管容积调制弧治疗方案的影响。所有计划均在带有80多叶准直器(MLC)的Elekta Synergy线性加速器的摩纳哥计划系统中完成。采用不同的门架角度增量(例如15°,20°,30°和40°)来完成容积调制弧光治疗(VMAT)计划。所有计划的其余参数均相似。比较结果。为了将计划质量与弧数进行比较,VMAT计划是通过单弧和双弧完成的,龙门角增量为20°。比较了60 Gy的总肿瘤体积剂量(GTV)和48 Gy的计划目标体积(PTV)。分析了GTV的剂量参数D98%,D95%,D50%和Dmax。研究了GTV的同质性指数(HI)和合格性指数(CI),并分析了PTV的98%和95%剂量。比较了脊髓的最大剂量和脐带(PRV脐带)的计划风险量。分析接受10 Gy,20 Gy和平均剂量的肺体积。比较了接受30 Gy和45 Gy的心脏体积。比较接受大于2 Gy和5 Gy的正常组织的体积。比较了交付计划所需的监视单元(MU)的数量。在剂量覆盖率,HI,CI和正常组织保留方面,具有较大机架角度计划的方案被证明优于较小机架角度计划的方案。弧数对计划质量没有任何影响。关键词:食道病例,龙门架角度增加,弧数,VMAT

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号