Resting Energy Expenditure per Lean Body Mass Determined by Indirect Calorimetry and Bioelectrical Impedance Analysis in Cats

机译:通过间接量热法和生物电阻抗分析确定的每只瘦体重的静息能量消耗

获取原文
   

获取外文期刊封面封底 >>

       

摘要

AbstractBackgroundResting energy expenditure (REE) approximates ≥60% of daily energy expenditure (DEE). Accurate REE determination could facilitate sequential comparisons among patients and diseases if normalized against lean body mass (LBM).Objective(1) Validate open-flow indirect calorimetry (IC) system and multifrequency bioelectrical impedance analysis (MF-BIA) to determine REE and LBM, respectively, in healthy nonsedated cats of varied body conditions; (2) normalize REE against LBM.AnimalsFifty-seven adult neutered domestic short-haired cats with stable BW.MethodsContinuous (45-min) IC-measurements determined least observed metabolism REE. Cage gas flow regulated with mass flow controllers was verified using nitrogen dilution; span gases calibrated gas measurements. Respiratory quotient accuracy was verified using alcohol combustion. IC-REE was compared to DEE, determined using doubly labeled water. MF-BIA LBM was validated against criterion references (deuterium, sodium bromide). Intra- and interassay variation was determined for IC and MF-BIA.ResultsMean IC-REE (175 ± 38.7 kcal; 1.5–14% intra- and interassay CV%) represented 61 ± 14.3% of DEE. Best MF-BIA measurements were collected in sternal recumbency and with electrodes in neck-tail configuration. MF-BIA LBM was not significantly different from criterion references and generated LBM interassay CV% of 6.6–10.1%. Over- and underconditioned cats had significantly (P ≤ .05) lower and higher IC-REE (kcal/kg) respectively, compared with normal-conditioned cats. However, differences resolved with REE/LBM (approximating 53 ± 10.3 kcal/LBM [kg]).Conclusions and Clinical ImportanceIC and MF-BIA validated herein reasonably estimate REE and LBM in cats. REE/LBM(kg) may permit comparison of energy utilization in sequential studies or among different cats.
机译:摘要背景静态能量消耗(REE)约等于每日能量消耗(DEE)的60%以上。如果针对瘦体重(LBM)进行标准化,则准确的REE测定可以促进患者和疾病之间的顺序比较。目的(1)验证开流间接量热(IC)系统和多频生物电阻抗分析(MF-BIA)以确定REE和LBM分别在身体状况各异的健康非镇静猫中使用; (2)使REE相对于LBM正常化。动物57只体重稳定的成年绝育成年家猫短毛猫。方法连续(45分钟)IC测量确定最少观察到的代谢REE。使用氮气稀释来验证由质量流量控制器调节的笼式气体流量;量程气体标定气体测量。使用酒精燃烧来验证呼吸商的准确性。将IC-REE与使用双标记水测定的DEE进行比较。 MF-BIA LBM已针对标准参考物(氘,溴化钠)进行了验证。测定了IC和MF-BIA的批内和批间差异。结果平均IC-REE(175±38.7kcal;批内和批间CV%为1.5-14%)占DEE的61±14.3%。最好的MF-BIA测量是在胸骨横卧且电极呈尾巴状的情况下进行的。 MF-BIA LBM与标准参考值无显着差异,并且产生的LBM测定间CV%为6.6-10.1%。与正常条件下的猫相比,过度适应和条件不足的猫的IC-REE(kcal / kg)分别显着降低(P≤.05)和更高。但是,REE / LBM的差异得以解决(约53±10.3kcal / LBM [kg])。结论和临床重要性IC和MF-BIA在本文中进行了合理评估,从而估计了猫的REE和LBM。 REE / LBM(kg)可以比较在连续研究中或不同猫之间的能量利用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号