...
首页> 外文期刊>Journal of Veterinary Internal Medicine >Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows
【24h】

Comparison of smartphone‐based and standard base‐apex electrocardiography in healthy dairy cows

机译:健康奶牛中基于智能手机的心电图和标准基础心电图的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background There is good diagnostic accuracy of smartphone‐based ECG in the evaluation of heart rate (HR), heart rhythm, and ECG values for humans, horses, dogs, and cats. Objectives Assess feasibility and reliability of a smartphone ECG device to evaluate HR expressed as beats per minute and ECG values in cows. Animals Fifty‐five healthy Holstein Friesian cows. Methods Prospective observational study. A standard base‐apex ECG was acquired for 60?seconds in each cow. A smartphone ECG tracing was recorded simultaneously using a single‐lead bipolar ECG recorder. All ECGs were reviewed by 1 blinded investigator. The following ECG variables were assessed: HR, P wave duration, PR interval, QRS complex and QT interval (milliseconds), P wave, and QRS complex polarity. Agreement between standard and smartphone ECG was evaluated by Cohen's k test and the Bland‐Altman test. Results Smartphone ECG tracings were interpretable in 89% of the recordings. Minimal differences of no clinical relevance were found between standard and smartphone ECG tracings regarding HR and duration of ECG waves and interval. Good agreement found in the evaluation of QRS complex polarity (85%) but not for P wave polarity ( k =?0.006). Artifacts were rare but of significantly higher frequency in smartphone ECG compared to standard ECG tracings (22% versus 0%; P =?.005). Conclusions and Clinical Importance Good quality single‐lead ECG tracings can be recorded by smartphone device in healthy cows. Smartphone tracings are reliable for evaluation of HR and selective ECG variables. Smartphone ECG can represent an additional tool for ECG screening in cows.
机译:背景技术基于智能手机的ECG在评估人,马,狗和猫的心律(HR),心律和ECG值方面具有良好的诊断准确性。目的评估智能手机ECG设备的可行性和可靠性,以评估表示为每分钟心跳数的HR和母牛的ECG值。动物55头健康的荷斯坦黑白花奶牛。方法进行前瞻性观察研究。每头母牛获取标准的基础心电图心电图持续60秒。使用单导联双极ECG记录器同时记录了智能手机ECG跟踪。一名盲人研究者对所有心电图进行了审查。评估以下ECG变量:心率,P波持续时间,PR间隔,QRS复数和QT间隔(毫秒),P波和QRS复数极性。标准和智能手机ECG之间的一致性通过Cohen的k检验和Bland-Altman检验进行了评估。结果在89%的记录中,可以解释智能手机ECG描记。在标准和智能手机心电图描记之间,关于心率,心电图波的持续时间和间隔,没有临床相关性的最小差异。在QRS复数极性的评估(85%)中发现了很好的一致性,但对于P波极性则没有(k =?0.006)。与标准ECG描记相比,智能手机ECG中的伪像很少见,但频率要高得多(22%对0%; P =?0.005)。结论和临床重要性通过智能手机设备可以在健康的奶牛中记录高质量的单导联心电图。智能手机跟踪对于评估HR和选择性ECG变量是可靠的。智能手机ECG可以代表奶牛ECG筛查的其他工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号