首页> 外文期刊>Journal of Veterinary Internal Medicine >Effect of Sample Storage on Blood Crossmatching in Horses
【24h】

Effect of Sample Storage on Blood Crossmatching in Horses

机译:样品储存对马血液交叉匹配的影响

获取原文
获取外文期刊封面目录资料

摘要

AbstractBackgroundBlood samples banked for up to 1 month are typically used to perform pretransfusion testing in humans and small animals, but this has not been validated using blood from horses.HypothesisCompatibility of equine blood samples is repeatable using fresh samples, and reproducible using donor blood samples stored for up to 4 weeks.AnimalsSix healthy adult horses.MethodsRandomized, blinded experimental study. Immunologic compatibility of the blood of all horses was assessed using a major and minor saline agglutination and hemolysin crossmatch using blood samples refrigerated for 0–4 weeks and fresh blood from the same horses. Crossmatch results were scored and then compared to identify changes of compatibility in each of the 4 tests. In addition, repeatability of the crossmatch technique itself was assessed by performing 6 iterations of this procedure in immediate succession with fresh blood from 3 horses.ResultsNo significant difference in crossmatch results was found using fresh blood (P = .39–1.00). Reproducibility was poor using blood stored for 1–4 weeks, especially in tests using stored erythrocytes (major antigen crossmatches), with significant differences from baseline at all weeks (P  .05); 13 of these differences were positive, indicating poorer compatibility.Conclusions and Clinical ImportanceEquine blood crossmatching is repeatable using fresh blood, although decreased apparent compatibility after storage makes exclusion of compatible donors more likely than mistaken administration of incompatible blood. These data suggest that fresh samples should be collected from potential donors before crossmatching equine blood.
机译:摘要背景通常保存长达1个月的血液样本通常用于在人和小型动物中进行输血前测试,但尚未使用马匹的血进行验证。动物长达4周动物六只健康的成年马。方法随机化,盲法实验研究。使用主要和次要的生理盐水凝集和溶血素的交叉配比评估所有马血的免疫学相容性,使用的是经过冷冻0至4周的血样以及来自同一匹马的新鲜血液。对交叉比赛的结果进行评分,然后进行比较以识别4种测试中每种兼容性的变化。此外,通过使用3匹马的新鲜血液立即连续进行6次此过程来评估交叉比赛技术本身的可重复性。结果使用新鲜血液在交叉比赛结果中没有发现显着差异(P = .39-1.00)。使用储存1-4周的血液的重现性很差,尤其是在使用储存的红细胞(主要抗原交叉匹配)的测试中,在所有周中均与基线有显着差异(P <.05);这些差异中有13个为阳性,表明相容性较差。结论和临床重要性尽管新鲜的储存后表观相容性降低,使得相容性供体被排除的可能性要比误配不相容血液的可能性高,但可以使用新鲜血液来重复进行马匹血液交叉匹配。这些数据表明,在交叉匹配马血之前,应从潜在的供体中收集新鲜样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号