Since chemical regeneration of condensate demineralizers produces a large quantity of radio-active liquid wastes, reducing the volume of such wastes has become a significant concern.In Japanese Improvement and Standardization BWR's, by installing a prefilter upstream from the condensate demineralizer, and improving construction materials and method of controlling water chemistry, the crud and ion load on the condensate demineralizer has been reduced.Since non-regenerated operation of the condensate demineralizer has been devised and tried on the No. 2 Unit of the Fukushima Daini Nuclear Power Station (2F-2) with variable resin measurement during every scheduled outage and each fuel cycle. The result has been a reduction of the number of drums to be disposed of to 1/5 the previous number.
机译:由于冷凝水脱盐器的化学再生会产生大量放射性液体废物,因此减少此类废物的体积已成为一个重大问题。在日本的“改进和标准化” BWR中,通过在冷凝水脱盐器的上游安装预过滤器并改善建筑材料和控制水化学的方法,减少了冷凝水脱盐器的结垢和离子负荷。由于已经设计了冷凝水脱盐器的非再生运行,并在福岛第一核电站2号机组(2F- 2)在每个计划的停机和每个燃料循环期间进行可变的树脂测量。结果是将要处理的感光鼓数量减少到先前数量的1/5。