Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was ?2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and ?2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed.
机译:背景技术无菌性松动是髋关节置换术中的最大问题之一。髋关节的旋转中心被认为会影响固定的寿命。这项研究的目的是比较骨水泥杯和非骨水泥杯固定技术对旋转中心位置的影响,因为骨水泥杯固定需要比无骨水泥技术去除更多的骨头来进行固体固定。方法我们回顾性比较了2007年我科分别采用骨水泥或非骨水泥杯固定术对25例和68例行人工髋关节置换术的患者的髋关节旋转中心的位置和数字射线照相图像分析。结果在术前和术后拍摄的影像中比较了旋转中心和髋臼泪滴之间的平均水平和垂直距离。非骨水泥固定患者的平均水平差为?2.63 mm(范围:-11.00 mm至10.46 mm,标准偏差为4.23 mm),患者的平均水平差为?2.84 mm(范围:-10.87至5.30 mm,标准偏差为4.59 mm)进行固定固定的人非骨水泥固定组和骨水泥固定组的平均垂直差分别为0.60毫米(范围:-20.15毫米至10.00毫米,标准偏差3.93毫米)和0.41毫米(范围:-9.26毫米至6.54毫米,标准偏差3.58毫米)。在本研究的93例患者中,两种固定方法在髋关节旋转中心位置上无显着差异。结论在该患者队列中,使用骨水泥固定术或非骨水泥固定术可以类似地恢复髋关节旋转中心,这表明该固定技术本身不会干扰旋转中心的位置。为了完全回答这个问题,需要对更多的患者进行进一步的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号