...
首页> 外文期刊>Journal of Orthopaedic Surgery Research >Comparison of compressive forces caused by various cannulated cancellous screws used in arthroscopic ankle arthrodesis
【24h】

Comparison of compressive forces caused by various cannulated cancellous screws used in arthroscopic ankle arthrodesis

机译:关节镜检查踝关节固定术中使用的各种空心松质螺钉引起的压力比较

获取原文
           

摘要

BackgroundWhen performing arthroscopic ankle arthrodesis for end-stage ankle arthritis, internal fixation is performed using bone screws after appropriate preparation.However, optimal characteristics of bone screws have not been examined in terms of pressure force. Objective comparisons of bone-screw performance may provide information on procedures for arthroscopic ankle arthrodesis. The study objectives were to determine whether it was possible to measure compressive force changes using the newly developed device and to infer all screw characteristics from measurement results when used in actual surgeries. In addition, we performed experiments on cadavers to verify whether the experimental results could be applied to the joints of living subjects. MethodsThree types of screws (S1, S2, and S3) were inserted into the unique measurement device, and the changes in pressure were measured for each 45° turn. Changes in pressure and maximum pressure force were recorded after the application of the screws. After reaching the maximum pressure in the simulated bone, further screw rotations were accompanied by a gradual pressure decrease to 0?MPa. We also measured pressure changes in a similar manner by inserting a miniature pressure sensor into the talocrural joints of cadavers. ResultsThe mean maximum pressure?±?standard deviation for S1, S2, and S3 were 0.832?±?0.164?MPa, 0.434?±?0.116?MPa, and 0.414?±?0.127?MPa, respectively. Pressure slopes to the maximum did not significantly differ between the screws in the simulated bone, and a subsequent pressure decrease to 0?MPa was significantly more rapid for S1 than for S2 and S3. Although pressure failure after the overtightening of screws was only observed in the simulated bone, patterns of pressure vs. rotation angle were similar in simulated and cadaveric bones. The pressure profile characteristics of three different screw types were determined. ConclusionsWe were able to measure the compressive force changes using the newly developed device when the screws were inserted. On the basis of the measurement results, we were able to infer the characteristics of all screws when used in actual surgery.
机译:背景技术进行关节镜检查踝关节关节固定术治疗终末期踝关节炎时,经过适当的准备工作后使用接骨螺钉进行内固定,然而,尚未根据压力对接骨螺钉的最佳特性进行检查。骨螺钉性能的客观比较可提供有关关节镜检查踝关节固定术的信息。研究目的是确定是否有可能使用新开发的设备来测量压力变化,并在实际手术中使用时从测量结果中推断出所有螺钉特性。此外,我们对尸体进行了实验,以验证实验结果是否可以应用于活体受试者的关节。方法将三种类型的螺钉(S1,S2和S3)插入唯一的测量设备中,并在每45°旋转时测量一次压力变化。拧上螺丝后记录压力和最大压力的变化。在模拟骨骼中达到最大压力后,进一步的螺钉旋转伴随压力逐渐降低至0?MPa。我们还通过将微型压力传感器插入尸体的滑膜关节来测量压力变化。结果S1,S2和S3的平均最大压力分别为0.832±0.164MPa,0.434±0.116MPa和0.414±0.127MPa。模拟骨骼中的螺钉之间的最大压力斜率没有显着差异,随后,S1的压力降低到0?MPa的速度明显快于S2和S3。尽管仅在模拟骨骼中观察到螺钉过度拧紧后的压力衰竭,但模拟骨骼和尸体骨骼中压力与旋转角度的关系却相似。确定了三种不同螺杆类型的压力曲线特征。结论插入螺钉后,我们能够使用新开发的设备测量压力变化。根据测量结果,我们能够推断出在实际手术中使用时所有螺钉的特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号