首页> 外文期刊>Journal of Medical Cases >Femoral Fracture Caused by Removal of Femoral Intramedullary Nail Made of Stainless Steel
【24h】

Femoral Fracture Caused by Removal of Femoral Intramedullary Nail Made of Stainless Steel

机译:去除不锈钢制成的股骨髓内钉引起的股骨骨折

获取原文

摘要

This is to report a case of femoral fracture caused by removal of a femoral intramedullary nail. The patient was a 28-year-old male. We performed intramedullary nailing for his femoral shafts fracture with an interlocking femoral nail made of stainless steel with fluted structure and roughened surface. The nail was removed 2 years and 5 months later, and fresh fracture lines were found in the postremoval radiograph. We suspected there existed problems with the structure of the intramedullary nail as well as late removal of the nail.J Med Cases. 2015;6(3):105-108doi: http://dx.doi.org/10.14740/jmc2059w
机译:这是一例因股骨髓内钉去除引起的股骨骨折的病例。该患者是一名28岁的男性。我们用不锈钢制成的带槽纹结构且表面粗糙的互锁股骨钉对股骨干骨折进行了髓内钉固定。指甲在2年零5个月后被移除,并且在切除后的X光片中发现了新的骨折线。我们怀疑髓内钉的结构以及指甲的后期去除均存在问题。 2015; 6(3):105-108doi:http://dx.doi.org/10.14740/jmc2059w